Variability of office, 24-hour ambulatory, and self-monitored blood pressure measurements.
نویسندگان
چکیده
BACKGROUND The diagnosis of hypertension is difficult when faced with several different blood pressure measurements in an individual. Using the average of several office measurements is recommended, although considerable uncertainty remains. Twenty-four-hour ambulatory monitoring is often considered the gold standard, but self-monitoring of blood pressure has been proposed as a superior method. AIM Determination of within-individual variability of blood pressure measured in the office, by ambulatory monitoring, and by a week of self-monitoring. DESIGN OF STUDY Retrospective analysis of a clinical trial of 163 subjects. METHOD Within-patient variability of office and ambulatory blood pressure was determined from measurements at 0 and 6 weeks. Subjects had performed self-monitoring of blood pressure twice each morning and evening, for at least 6 weeks; variability was determined from the means of week 1 and week 6. RESULTS The within-individual coefficients of variation (CVs) for systolic blood pressure were: office, 8.6%; ambulatory, 5.5%; self, 4.2%. Equivalent values for diastolic blood pressure were 8.6%, 4.9%, and 3.9%. CVs tended to be lower with longer self-monitoring duration, and higher with longer intervals between self-monitoring. CONCLUSION Office blood pressure is impractical for precise assessment, as 10-13 measurements are required to give the accuracy required for rational titration of antihypertensive drugs. Twenty-four-hour ambulatory monitoring is better than a single office measurement, but considerable uncertainty remains around the estimate. A week of self-monitoring appears to be the most accurate method of measuring blood pressure, but remains imperfect. Further research may identify superior self-monitoring schedules. Given the inherent accuracy in blood pressure measurement, the importance of considering overall cardiovascular risk is emphasised.
منابع مشابه
Relationship of 24-hour ambulatory blood pressure and heart rate with markers of hepatic function in cirrhotic patients
BACKGROUND There is evidence that in cirrhotic patients, certain hemodynamic parameters, such as blood pressure and heart rate, are related to the severity of liver disease. This study investigated whether non-invasive 24-hour ambulatory blood pressure and heart rate are more closely associated with markers of liver disease severity than conventional office measurements. METHODS Ambulatory pa...
متن کاملOut-of-office blood pressure: from measurement to control
Hypertension is an important risk factor for the development of cardiovascular disease, and is a major cause of morbidity and mortality worldwide. Traditionally, hypertension diagnosis and treatment and clinical evaluations of antihypertensive efficacy have been based on office blood pressure (BP) measurements; however, there is increasing evidence that office measures may provide inadequate or...
متن کاملEffect of Olmesartan-Based Therapies on Therapeutic Indicators Obtained Through Out-of-Office Blood Pressure
Ambulatory blood pressure (BP) correlates more significantly with hypertension-associated cardiovascular mortality and morbidity than BP obtained in the doctor's office. Assessing ambulatory BP, either through 24-h monitoring or through protocolized self-measurement at home, is essential in diagnosing and monitoring patients with hypertension. Several ambulatory BP-derived indicators are relate...
متن کاملIs siesta masking masked hypertension?
To the Editor: Banegas et al,1 for the Spanish Society of Hypertension Ambulatory Blood Pressure Monitoring Registry Investigators, have examined the sensitivity and specificity of office blood pressure measurements in assessing control of hypertension in treated patients. The “gold standard” reference was the daytime component of a 24-hour ambulatory blood pressure monitoring. In this manner, ...
متن کاملAmbulatory Blood Pressure Normality and Comparison With Other Measurements
Previous studies have reported results on 24-hour ambulatory blood pressure (ABP) in Europe and Japan, but no data exists from South America. In this study, we conducted a population survey to identify reference values and to compare ambulatory blood pressure with clinic, home, and self-measured values. A random sample of 2650 adults was selected among 190 000 people covered by our prepaid heal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of general practice : the journal of the Royal College of General Practitioners
دوره 60 578 شماره
صفحات -
تاریخ انتشار 2010