Enhancement of Heat Transfer by an Electric Field for a Drop Translating at Intermediate Reynolds Number

نویسندگان

  • Rajkumar Subramanian
  • M. A. Jog
چکیده

The enhancement of heat transfer by an electric field to a spherical droplet translating at intermediate Reynolds number is numerically investigated using a finite volume method. Two heat transfer limits are considered. The first limit is the external problem where the bulk of the resistance is assumed to be in the continuous phase. Results show that the external Nusselt number significantly increases with electric field strength at all Reynolds numbers. Also, the drag coefficient increases with electric field strength. The enhancement in heat transfer is higher with lower ratio of viscosity of the dispersed phase to the viscosity of the continuous phase. The second heat transfer limit is the internal problem where the bulk of the resistance is assumed to be in the dispersed phase. Results show that the steady state Nusselt number for a combined electrically induced and translational flow is substantially greater than that for purely translational flow. Furthermore, for a drop moving at intermediate Reynolds number, the maximum steady state Nusselt number for a combined electrically induced and translational flow is slightly greater than that for a purely electric field driven motion in a suspended drop. DOI: 10.1115/1.2033906

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of the thermo-hydraulic behavior of the fluid flow over a square ribbed channel

The thermo-hydraulic behavior of the air flow over a two dimensional ribbed channel wasnumerically investigated in various rib-width ratio configurations (B/H=0.5-1.75) atdifferent Reynolds numbers, ranging from 6000 to 18000. The capability of differentturbulence models, including standard k-ε, RNG k-ε, standard k-ω, and SST k-ω, inpredicting the heat transfer rate was compared with the experi...

متن کامل

Heat transfer in MHD square duct flow of nanofluid with discrete heat sources

The effect of thermal and solutal buoyancy induced by a discrete source of heat and mass transfer in a square duct under the influence of magnetic field, especially at the turbulent regime for the first time is reported. Al2O3/water nanofluid is used with constant heat flux from three discrete heat sources. In the present study, the effects of Reynolds number (100 to 3000), particle volume frac...

متن کامل

Experimental Investigation of Mixed Convection Heat Transfer in Vertical Tubes by Nanofluid: Effects of Reynolds Number and Fluid Temperature

An experimental investigation was carried out to study mixed convection heat transfer from Al2O3-water nanofluid inside a vertical, W-shaped, copper-tube with uniform wall temperature. The tests covered different ranges of some involved parameters including Reynolds number, temperature and particles volume fraction. The results showed that the rate of heat transfer coefficient improved with Rey...

متن کامل

A numerical investigation of heat transfer and pressure drop in a novel cylindrical heat sink with helical minichannels

This study numerically investigated heat transfer and fluid flow characteristics in a novel cylindrical heat sink with helical minichannels for the laminar flow of fluid with temperature-dependent properties. A finite volume method was employed to obtain the solution of governing equations. The effects of helical angle, channel aspect ratio, and Reynolds number, which were regarded as main para...

متن کامل

Investigation of convective heat transfer, pressure drop and efficiency of ZnO/water nanofluid in alternating elliptical axis tubes

In this study, for the first time, the heat transfer and the pressure drop of zinc oxide nanoparticles in alternating elliptical axis (AEA) tube have been investigated experimentally. The zinc oxide nanoparticles were at volumetric concentrations 1% and 2%. The base fluid was heat transfer oil and the experiments were conducted at constant wall temperature. Also, the study was done in Reynolds ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005