Predictability, Stability and Safety of MyoRing Implantation in Keratoconic Eyes During One Year Follow-Up

نویسندگان

  • Sahar Mojaled Nobari
  • Consuelo Villena
چکیده

Purpose: To assess the stability of visual and refractive outcomes that was compared between three and 12 months after MyoRing implantation in moderate and severe keratoconus Methods: This study included 54 eyes of 50 patients (27 males and 23 females) with stage II and III keratoconus who underwent MyoRing (Dioptex GmbH) implantation. Clinical outcomes including uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refraction, spherical equivalent (SE) and mean keratometry (k)readings were compared preoperatively and postoperatively (follow-up times were at 1, 3, 6 and 12 months postoperation). Results: The mean age was 28.48±6.3. The mean UDVA (logMAR) and the mean CDVA (logMAR) improved significantly from 1.20±0.24 to 0.20±0.09 and from 0.58±0.22 to 0.14±0.06, respectively (p<0.001). Both SE and the maximum keratometry (k)-reading decreased significantly by six diopters (p<0.001). There was no significant difference in visual and refractive outcomes between three and 12 months postoperatively. Twelve months after MyoRig implantation the predictability was 47 eyes (87%) within ±1.00 D and 31 eyes (57%) within ±0.50 D of emmetropia. Conclusion: MyoRing implantation in keratoconic patients improves SE, UDVA and CDVA significantly. Additionally, the improvement in UDVA was remarkable (approximately 10 lines). The procedure was safe and effective in treatment of patients with moderate and severe keratoconus. The visual and refractive outcomes remained stable between three and 12 months postoperatively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Outcomes after Complete Intracorneal Ring Implantation and Corneal Collagen Cross-Linking in an Intrastromal Pocket in One Session for Keratoconus

Purpose. The aim of this work was to evaluate the results after combined surgery implantation of full rings and CXL in one session in a group of patients with keratoconus during a 12-month follow-up. Material and Methods. The study included 22 eyes of 20 keratoconic patients, mean age of 28.41 (from 18 to 50) years. A full ring was inserted and afterwards 0.1% riboflavin solution was injected i...

متن کامل

Characteristics of Astigmatism after MyoRing Implantation

Considering the rising number of MyoRing implantation procedures in keratoconic corneas and the refractive outcomes associated with this treatment modality, this study aimed to evaluate and compare the magnitude and axis orientation of total and corneal astigmatism between before and after MyoRing implantation in 34 eyes of 28 patients with keratoconus (KCN) (mean age: 29.41 ± 7.0 years). The i...

متن کامل

Three-Year Follow-Up of Posterior Chamber Toric Phakic Intraocular Lens Implantation for Moderate to High Myopic Astigmatism

PURPOSE To assess the 3-year clinical outcomes of toric phakic intraocular lens (Visian ICL™; STAAR Surgical) implantation for moderate to high myopic astigmatism. METHODS This retrospective study evaluated fifty eyes of 28 patients who underwent toric ICL implantation for the correction of moderate to high myopic astigmatism and who regularly returned for postoperative examination. Before, a...

متن کامل

Toric implantable collamer lens for high myopic astigmatism in keratoconic patients after six months.

BACKGROUND The aim was to evaluate the safety, efficacy, stability and predictability of posterior chamber collagen copolymer phakic intraocular lens (pIOL) implantation to correct myopia and myopic astigmatism associated with keratoconus. METHODS The unaided vision and visual acuity, refraction and adverse events were measured in 22 keratoconic eyes of 14 patients after using an implantable ...

متن کامل

One-year results of intrastromal corneal ring segment implantation (KeraRing) using femtosecond laser in patients with keratoconus.

PURPOSE To report the results of intrastromal corneal ring segment [ICRS] (KeraRing; Mediphacos, Belo Horizonte, Brazil) implantation using a femtosecond laser (IntraLase Corp, Irvine, California, USA) in keratoconic patients. DESIGN Retrospective, noncomparative, interventional study. METHODS Thirty-two keratoconic patients (50 eyes) who underwent ICRS insertion using a femtosecond laser f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017