A Technique for Improving Input Current Zero-crossing Distortion of Boost PFC Converters for Airborne System

نویسندگان

  • Bin Zhou
  • Hongtao Shan
چکیده

In airborne AC power system, input current may distort at the vicinity of input voltage zero crossing in Power Factor Correction (PFC) converter. This paper is analyzed the essential causes of the zero-crossing distortion and points out that the major causes are the value of inductor and the phase displacement between input current and input voltage. By adopting parallel interleaving technique, it can decrease the inductor and increase the equivalent switching frequency, improve input current zero-crossing distortion effectively. The effectiveness of this method is verified by simulation and experiments. The experiment results are demonstrated that it can make input current harmonics meet relevant standards so it can be applied in airborne system. Key wordsAirborne System; Zero-crossing Distortion; Value of Inductor; Phase Displacement; Parallel Interleaving

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Predictive Control of a Series-Interleaved Multi-Cell Three-Level Boost Power Factor Correction Converter

This paper presents a new predictive power-factorcorrection (PFC) controller for series-interleaved three-level boost (TLB) converters. Compared to the state-of-the-art TLB PFC controllers, where a two-cycle prediction and a detection of an operating region are necessary, the proposed controller achieves a low total harmonic distortion of the input current by using a single equation to predict ...

متن کامل

The Zero-Crossing Distortion and One Cycle Control in Single-phase PFC

Input current distortion in the vicinity of input voltage zero crossing of Boost single-phase active power factor corrected rectifier in high line frequency is studied based on one cycle control method in this paper. The current loop model and input admittance model of active power correction based on one cycle control is particularly analyzed. The results point out that its equivalent power st...

متن کامل

Generalized Average-current-mode Control of Single-phase Ac-dc Boost Converters with Power Factor Correction

The dissertation presents a generalized average-current-mode control technique (GACMC), which is an extension of the average-current-mode control (ACMC) for single-phase ac-dc boost converters with power factor correction (PFC). Traditional ACMC is generalized in a sense that it offers improved performance in the form of significant reduction of the current control loop bandwidth requirement fo...

متن کامل

Harmonic Optimization by Single Phase Improved Power Quality AC-DC Power Factor Corrected Converters

33 ABSTRACT This paper presents a comparative evaluation of five topologies of single-phase AC-DC boost converters having power factor correction (PFC). These converter topologies are evaluated on the basis of performance and their salient features are discussed to analyze their applicability. The techniques not only help to develop a deeper understanding of these converters but also to evaluat...

متن کامل

Performance of Three Level Integrated AC-DC Converter with Hysteresis Current Control

In this paper, Performance of three-level integrated ac–dc converter with Hysteresis Current Control Technique is presented. The proposed converter combines with the operation of the boost power factor correction and the three-level dc–dc converter. By the implementation of Hysteresis Current controller, the switching sequence is under controlled condition and the output voltage of the proposed...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015