Near Azeotrope Refrigerants to Replace R502 in Commercial Refrigeration

نویسنده

  • S. G. Sundaresan
چکیده

The Refrigerant RS02, an azeotrope of CFCllS and HCFC22, is an important refrigerant in commercial refrigeration, especially for low temperature applications using single stage compressors. current users of R502 are faced with an earlier than ~nticipated phase-out and are under great pressure to find suitable alternates for retrofit and o.E.M. (new) applications. Single components like HCFC12S, HFC143a, and HFC32 are not viable candidates, Some candidates which are being evaluated are near azeotropes containing HCFC22 and propane as components. This paper discusses the challenges involving the near azeotropes and also includes status on lubricants and materials compatibility requirements. The final solution for R502 involves finding a suitable zero ozone depletion potential refrigerant candidate with an appropriate lubricant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of the Operating Characteristics of a Low Evaporation Temperature R404A Refrigeration System

A refrigeration system which was originally designed using R502 as refrigerant was rebuilt to adapt the special requirements of R404A. The experiments, both for R502 and R404A, on this system were done and some parameters such as evaporating temperature, condensing temperature, discharge temperature, compressor input power and so on were measured under different working conditions. Then the ope...

متن کامل

The Study of Using Carbon Dioxide as the Alternative of R502 in Industrial Refrigeration Applications

This paper presents the simulation study and comparison of C02 and R502 as refrigerants. At first, as a single stage vapor compression refrigeration cycle's refrigerant, C02 can be used in subcritical and transcritical situations. The performances are studied completely. The results show that C02 has the same or better performance compared to R502's in certain temperature ranges. Finally C02 an...

متن کامل

Laboratory Evaluation and Field Tests of Replacements for R22 and R502

Per Lundqvist Dr., Lars Herbe M.Sc, The Royal Institute ofTechnology, Dept. of Energy Technology, S-100 44, Stockholm, Sweden Fax: +46 8 20 30 07 Tel: +46 8 790 74 52 Email: [email protected] There are several important issues when dealing with new refrigerants in a retrofit situation. This paper is however restricted to system performance and a discussion of methods suitable to determine ...

متن کامل

Drop-In Substitutes for R502: The Role of HCFC22 and HC290

R502 is due to be banned in the near future, and ti)e need for an immediately available and easy-to-use alternative is becoming more and more urgent. Retrofitting refrigerating units can prove easier and less expensive if the mineral or alkylbenzene lubricants usually adopted with R502 have a certain miscibility in the drop-in mixtures. This paper examines the near-azeotropic mixture Rl43a/290/...

متن کامل

Discharge Gas Temperature Control in Reciprocating Hermetic Compressors Modified for R134a/R22 Refrigerants Operation as Substitutes of Present R12/R502

Discharge gas temperature value is an indicator of compressor safe operating conditions, particularly on R12 and R502 commercial applications. These refrigerants will be replaced very soon by R134a and R22 respectively, also if R22 is not considered a final solution. High discharge temperatures are typical in LBP-R22 hermetic compressors operating at low evaporating temperature as low as -40"C;...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014