Determination of birefringence and absolute optic axis orientation using polarization-sensitive optical coherence tomography with PM fibers.

نویسندگان

  • Jun Zhang
  • Shuguang Guo
  • Woonggyu Jung
  • J Nelson
  • Zhongping Chen
چکیده

A novel polarization-sensitive optical coherence tomography (PS-OCT) system was developed using polarization maintaining (PM) optical fibers and fiber coupler to measure birefringence properties of samples. Polarization distortion due to PM fibers and coupler can be calibrated with different polarization states during two consecutive A-scans. By processing the analytical interference fringe signals derived from two orthogonal polarization detection channels, the system can be used to measure phase retardation and optic axis orientation. Standard wave plates with different orientation and retardation were used as samples to test the system and calibrating method. We have also applied this system to image biological sample such as beef tendon.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optic axis determination accuracy for fiber-based polarization-sensitive optical coherence tomography.

We present a generalized analysis of fiber-based polarization-sensitive optical coherence tomography with an emphasis on determination of sample optic axis orientation. The polarization properties of a fiber-based system can cause an overall rotation in a Poincaré sphere representation such that the plane of possible measured sample optic axes for linear birefringence and diattenuation no longe...

متن کامل

Polarization-sensitive spectral-domain optical coherence tomography using a single line scan camera.

Polarization-sensitive optical coherence tomography can be used to measure the birefringence of biological tissue such as the human retina. Previous measurements with a time-domain polarization-sensitive optical coherence tomography system revealed that the birefringence of the human retinal nerve fiber layer is not constant, but varies as a function of location around the optic nerve head. Her...

متن کامل

Jones matrix analysis for a polarization-sensitive optical coherence tomography system using fiber-optic components.

We present an analysis for polarization-sensitive optical coherence tomography that facilitates the unrestricted use of fiber and fiber-optic components throughout an interferometer and yields sample birefringence, diattenuation, and relative optic axis orientation. We use a novel Jones matrix approach that compares the polarization states of light reflected from the sample surface with those r...

متن کامل

Depth-resolved birefringence and differential optical axis orientation measurements with fiber-based polarization-sensitive optical coherence tomography.

Conventional polarization-sensitive optical coherence tomography (PS-OCT) can provide depth-resolved Stokes parameter measurements of light reflected from turbid media. A new algorithm that takes into account changes in the optical axis is introduced to provide depth-resolved birefringence and differential optical axis orientation images by use of fiber-based PS-OCT. Quaternion, a convenient ma...

متن کامل

Jones-matrix imaging of biological tissues with quadruple-channel optical coherence tomography.

Two-dimensional depth-resolved Jones-matrix images of scattering biological tissues were measured with novel double-source double-detector polarization-sensitive optical coherence tomography (OCT). The Jones matrix can be determined in a single scan with this OCT system. The experimental results show that this system can be effectively applied to the measurement of soft tissues, which are less ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics express

دوره 11 24  شماره 

صفحات  -

تاریخ انتشار 2003