Use of effective dose in medicine.

نویسندگان

  • J Harrison
  • P O Lopez
چکیده

This paper does not necessarily reflect the views of the International Commission on Radiological Protection. The protection quantity 'effective dose' was developed by the International Commission on Radiological Protection (ICRP) for use in the radiological protection of workers and the public. In this context, it is used as a risk-adjusted dosimetric quantity to optimise protection, comparing received or planned doses with constraints, reference levels, and limits expressed in the same quantity. Considering exposures incurred during medical procedures, effective dose can be of practical value for comparing: doses from different diagnostic examinations and interventional procedures; the use of similar technologies and procedures in different hospitals and countries; and the use of different technologies for the same medical examination, provided that the representative patients or patient populations for which the effective doses are derived are similar with regard to age and sex. However, as stated in ICRP Publication 103, '… risk assessment for medical diagnosis and treatment… is best evaluated using appropriate risk values for the individual tissues at risk and for the age and sex distribution of the individuals undergoing the medical procedures'. This topic was explored in a session of the First ICRP Symposium with arguments for and against the use of a new quantity referred to as 'effective risk', and examination of variations in estimated risk for different diagnostic procedures according to the age and sex of the exposed individuals. This paper restates the primary purposes of effective dose, and summarises estimates of variation in individual risk from medical procedures. The authors support the judicious use of effective dose as an indicator of possible risk, but caution against the use of effective risk as compared with the calculation of scientific best estimates of risk with consideration of associated uncertainties.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiation exposure from diagnostic nuclear medicine examinations in Golestan province

Introduction: The aim of present study was to estimate effective dose from most common procedures performed in nuclear medicine departments of Golestan province. Methods: Data of nuclear medicine procedures performed in 2 nuclear medicine departments in Golestan province were collected during 4 years. Effective dose, collective effective dose and effective dose per examination were calculated ...

متن کامل

Thyroid dose and dose reduction method from CT scan of head and neck

Introduction: Computed tomography (CT) consists of 11% of all imaging methods, but accounts for approximately 67% of radiation exposure due to diagnostic cases. More than one-third of all CT scans are done in the head and neck area. The thyroid gland is irradiated during CT head and neck. According to studies, this gland has the highest levels of radiation-induced cancer, and i...

متن کامل

Measurement of Entrance Skin Dose and Effective Dose in The most Common Diagnostic radiology Examinations in Jiroft, Iran

Introduction: Medical uses of radiation have grown very rapidly over in the past two decades, medical uses represent the largest source of exposure to people, The most important methods in medical diagnosis are the useses of diagnostic radiology exams. Although the use of these methods is very beneficial for the treatment of patients, but ionizing radiation produces ion pairs, ...

متن کامل

Assessment of whole-body occupational radiation exposures in nuclear medicine practices of Bangladesh during 2010-2014

Introduction: Occupational exposure to ionizing radiation due to medical activities (both diagnostic and therapeutic procedures) has increased sharply in recent years. Among the occupationally exposed workers in these fields, those most affected by this increased exposure to ionizing radiation are nuclear medicine workers. In this study, annual average effective dose, annual collective effectiv...

متن کامل

Size specific dose estimate (SSDE) for estimating patient dose from CT used in myocardial perfusion SPECT/CT

Objective(s): Size specific dose estimate (SSDE) is a new parameter that includes patient size factor in its calculation. Recent studies have produced mixed results on the utility of SSDE, especially when automatic exposure control (AEC) was used. The objective of the study was to find out if there is a relationship between patient size and each of the parameters, SSDE...

متن کامل

Staff and patient absorbed doses due to diagnostic nuclear medicine procedures

Background: Annual patient effective dose equivalent can be considered as a quantitative physical parameter describing the activities performed in each nuclear medicine department. Annual staff dose equivalent could be also considered as a parameter describing the amount of radiation risk for performing the activities. We calculated the staff to patient dose equivalent ratio to be used as a phy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of the ICRP

دوره 44 1 Suppl  شماره 

صفحات  -

تاریخ انتشار 2015