Impact of CT based attenuation correction on quantitative assessment of DaTSCAN ((123)I-Ioflupane) imaging in diagnosis of extrapyramidal diseases.

نویسندگان

  • Małgorzata Bieńkiewicz
  • Magdalena Górska-Chrzastek
  • Jakub Siennicki
  • Agata Gajos
  • Andrzej Bogucki
  • Alina Mochecka-Thoelke
  • Anna Płachcińska
  • Jacek Kuśmierek
چکیده

The quality of visually and semi-quantitatively assessed DaTSCAN images is crucial for differential diagnostics of extrapyramidal diseases. Neuroimaging with the use of presynaptic tracers of the dopaminergic system provides evidence of nigrostriatal degeneration and may support the clinical diagnosis of Parkinsonism. During the last two years (2007-2008) we tried to elaborate the optimal methodology of SPECT/CT examination with the use of DaTSCAN ((123)I-Ioflupane), and we sought to evaluate the effect of the reconstruction and attenuation correction method on semi-quantitative measures of relative uptake in the striatum. In a present study, we retrospectively studied DaTSCAN scans of 44 consecutive patients with clinical indications of Parkinson's disease or uncertain Parkinsonian syndromes. The quality of DaTSCAN images reconstructed with the use of ordered-subset expectation maximization reconstruction technique (OSEM) with attenuation correction based on CT maps was found to be superior to that provided by the commonly applied filtered backprojection method (FBP) with Chang attenuation correction. OSEM reconstructed transverse slices were more legible for clinical interpretation because of increased contrast and improved delineation between striatum structures. Semi-quantitative assessments of relative striatum uptake for OSEM reconstructed slices secured better intra-operator reproducibility than that obtained by FBP method.

منابع مشابه

Clinical utility of dopamine transporter single photon emission CT (DaT-SPECT) with (123I) ioflupane in diagnosis of parkinsonian syndromes

The diagnosis of movement disorders including Parkinson's disease (PD) and essential tremor is determined through clinical assessment. The difficulty with diagnosis of early PD has been highlighted in several recent clinical trials. Studies have suggested relatively high clinical diagnostic error rates for PD and essential tremor. This review was undertaken to clarify the utility of DaT-SPECT i...

متن کامل

Clinical utility of dopamine transporter single photon emission CT (DaT-SPECT) with (I) ioflupane in diagnosis of parkinsonian syndromes

To cite: Bajaj N, Hauser RA, Grachev ID. J Neurol Neurosurg Psychiatry Published Online First: [please include Day Month Year] doi:10.1136/jnnp2012-304436 ABSTRACT The diagnosis of movement disorders including Parkinson’s disease (PD) and essential tremor is determined through clinical assessment. The difficulty with diagnosis of early PD has been highlighted in several recent clinical trials. ...

متن کامل

CT-Based Attenuation Correction in I-123-Ioflupane SPECT

PURPOSE Attenuation correction (AC) based on low-dose computed tomography (CT) could be more accurate in brain single-photon emission computed tomography (SPECT) than the widely used Chang method, and, therefore, has the potential to improve both semi-quantitative analysis and visual image interpretation. The present study evaluated CT-based AC for dopamine transporter SPECT with I-123-ioflupan...

متن کامل

123-I Ioflupane (Datscan®) Presynaptic Nigrostriatal Imaging in Patients with Movement Disorders

123-I Ioflupane (Datscan®) presynaptic imaging has been shown to have a significant utility in the assessment of patients with movement disorders I Ioflupane SPECT is able to distinguish between Parkinson’s disease (PD) and other forms of parkinsonism without degeneration of the nigrostriatal pathway, including a common movement disorder such as essential tremor, and to assess disease progressi...

متن کامل

Computed tomography based attenuation correction in PET/CT: Principles, instrumentation, protocols, artifacts and future trends

  The advent of dual-modality PET/CT imaging has revolutionized the practice of clinical oncology, cardiology and neurology by improving lesions localization and the possibility of accurate quantitative analysis. In addition, the use of CT images for CT-based attenuation correction (CTAC) allows to decrease the overall scanning time and to create a noise-free attenuat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:
  • Nuclear medicine review. Central & Eastern Europe

دوره 11 2  شماره 

صفحات  -

تاریخ انتشار 2008