Effect of observing change from comparison mammograms on performance of screening mammography in a large community-based population.

نویسندگان

  • Bonnie C Yankaskas
  • Ryan C May
  • Jeanine Matuszewski
  • J Michael Bowling
  • Molly P Jarman
  • Bruce F Schroeder
چکیده

PURPOSE To evaluate the effect of comparison mammograms on accuracy, sensitivity, specificity, positive predictive value (PPV(1)), and cancer detection rate (CDR) of screening mammography to determine the role played by identification of change on comparison mammograms. MATERIALS AND METHODS This HIPAA-compliant and institutional review board-approved prospective study was performed with waiver of patient informed consent. A total of 1,157,980 screening mammograms obtained between 1994 and 2008 in 435,183 women aged at least 40 years were included. Radiologists recorded presence of comparison mammograms and change, if seen. Women were followed for 1 year to monitor cancer occurrence. Performance measurements were calculated for screening with comparison mammograms versus screening without comparison mammograms and for screening with comparison mammograms that showed a change versus screening with comparison mammograms that did not show a change while controlling for age, breast density, and data clustering. RESULTS Comparison mammograms were available in 93% of examinations. For screening with comparison mammograms versus screening without comparison mammograms, CDR per 1000 women was 3.7 versus 7.1; recall rate, 6.9% versus 14.9%; sensitivity, 78.9% versus 87.4%; specificity, 93.5% versus 85.7%; and PPV(1), 5.4% versus 4.8%. For screening with comparison mammograms that showed a change versus screening with comparison mammograms that did not show a change, CDR per 1000 women was 25.4 versus 0.8; recall rate, 41.4% versus 2.0%; sensitivity, 96.6% versus 43.5%; specificity, 60.4% versus 98.1%; and PPV(1), 6.0% versus 3.9%. Detected cancers with change were 21.1% ductal carcinoma in situ and 78.9% invasive carcinoma. Detected cancers with no change were 19.3% ductal carcinoma in situ and 80.7% invasive carcinoma. CONCLUSION Performance is affected when change from comparison mammograms is noted. Without change, sensitivity is low and specificity is high. With change, sensitivity is high, with a high false-positive rate (low specificity). Further work is needed to appreciate changes that might indicate cancer and to identify changes that are likely not indicative of cancer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Deep learning-based CAD systems for mammography: A review article

Breast cancer is one of the most common types of cancer in women. Screening mammography is a low‑dose X‑ray examination of breasts, which is conducted to detect breast cancer at early stages when the cancerous tumor is too small to be felt as a lump. Screening mammography is conducted for women with no symptoms of breast cancer, for early detection of cancer when the cancer is most treatable an...

متن کامل

SHIRAZ BREAST CANCER STUDY PART II: SCREENING MAMMOGRAPHY IN A OPULATIONBASED BREAST CANCER SURVEY

The purpose of this study was to assess the detection rate of mammography in breast cancer and the attendance rate in response to the call for screening mammography in females before the development of symptoms. One-thousand four-hundred and thirty-eight women over 35 years of age who had no complaint and had normal breast examinations were called for mammography. Out of the 10,000 women u...

متن کامل

Mammography Screening in a Large Health System Following the U.S. Preventive Services Task Force Recommendations and the Affordable Care Act

BACKGROUND Practice recommendations for mammography screening were issued by the U.S. Preventive Services Task Force in 2009 and expansion of insurance coverage was provided under the Patient Protection and Affordable Care Act soon thereafter, yet the influence of these changes on screening practices in the United States is not known. METHODS To determine changes in mammography screening and ...

متن کامل

Clinical Performance of Synthesized Two-dimensional Mammography Combined with Tomosynthesis in a Large Screening Population.

Purpose To compare the clinical performance of synthesized two-dimensional (s2D) mammography combined with digital breast tomosynthesis (DBT) with that of full-field digital mammography (FFDM) alone and FFDM combined with DBT in a large community-based screening population by analyzing recall rate, positive predictive value, and cancer detection rate. Materials and Methods This was a retrospect...

متن کامل

بررسی رفتار غربالگری ماموگرافی بر اساس مدل مراحـل تغییر در زنان بالای 40 سال شهر اصفهان: یک مطالعه‌ی مبتنی بر جمعیت

Background and Objective: Breast cancer is the most common cancer and the second leading cause of cancer death among women worldwide. Mammography is a sensitive and specific test that is used for early diagnosis of breast cancer. Mammography screening behavior is one of the behaviors that early study on its stage of change can be used in proper planning and effective interventions for performin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 261 3  شماره 

صفحات  -

تاریخ انتشار 2011