sEMG Sensor Using Polypyrrole-Coated Nonwoven Fabric Sheet for Practical Control of Prosthetic Hand

نویسندگان

  • Yinlai Jiang
  • Masami Togane
  • Baoliang Lu
  • Hiroshi Yokoi
چکیده

One of the greatest challenges of using a myoelectric prosthetic hand in daily life is to conveniently measure stable myoelectric signals. This study proposes a novel surface electromyography (sEMG) sensor using polypyrrole-coated nonwoven fabric sheet as electrodes (PPy electrodes) to allow people with disabilities to control prosthetic limbs. The PPy electrodes are sewn on an elastic band to guarantee close contact with the skin and thus reduce the contact electrical impedance between the electrodes and the skin. The sensor is highly customizable to fit the size and the shape of the stump so that people with disabilities can attach the sensor by themselves. The performance of the proposed sensor was investigated experimentally by comparing measurements of Ag/AgCl electrodes with electrolytic gel and the sEMG from the same muscle fibers. The high correlation coefficient (0.87) between the two types of sensors suggests the effectiveness of the proposed sensor. Another experiment of sEMG pattern recognition to control myoelectric prosthetic hands showed that the PPy electrodes are as effective as Ag/AgCl electrodes for measuring sEMG signals for practical myoelectric control. We also investigated the relation between the myoelectric signals' signal-to-noise ratio and the source impedances by simultaneously measuring the source impedances and the myoelectric signals with a switching circuit. The results showed that differences in both the norm and the phase of the source impedance greatly affect the common mode noise in the signal.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Robust Control of a Prosthetic Hand Based on a Hybrid Adaptive Finger Angle Estimation

This paper presents a robust control approach to control the movement of a prosthetic hand based on an estimation of the finger angles using surface electromyographic (sEMG) signals. All the available prosthesis uses the motion control strategy which is pre-programmed get initiated when some threshold value of the measured sEMG signal is reached for a particular motion set. Here we use a novel ...

متن کامل

Detection of napropamide by microwave resonator sensor using carbon nanotube – polypyrrole- chitosan layer

This paper presents the design and fabrication of proximity coupled feed disk resonator coated with Multi Walled Carbon Nanotubes (MWCNTs) and Polypyrrole-Chitosan (PPy-CHI) layers as a napropamide sensor. Computer Simulation Technology (CST) microwave studio was used to obtain the best design of disk resonator and feed line position in 5 GHz resonant frequency. Also, MWCNTs - PPy-CHI layers we...

متن کامل

Grip Force and 3D Push-Pull Force Estimation Based on sEMG and GRNN

The estimation of the grip force and the 3D push-pull force (push and pull force in the three dimension space) from the electromyogram (EMG) signal is of great importance in the dexterous control of the EMG prosthetic hand. In this paper, an action force estimation method which is based on the eight channels of the surface EMG (sEMG) and the Generalized Regression Neural Network (GRNN) is propo...

متن کامل

Lipase Production by Acinetobacter radioresistens in the Presence of a Nonwoven Fabric.

Lipase production by Acinetobacter radioresistens was performed in a 2-L tank fermentor equipped with a nonwoven fabric, which was made of nylon 6 fiber and coated with a hydrophobic acrylic resin. The fermentation medium contained 2% (v/v) n-hexadecane as the carbon source. The use of the nonwoven fabric was intended for the dispersion of hydrocarbons; thus, the contact surface for the cells t...

متن کامل

Mite penetration of different types of material claimed as mite proof by the Siriraj chamber method.

BACKGROUND There are different materials and principles used in the construction of bed encasings. Although these covers claim to have antimite properties, they might not be mite proof. OBJECTIVE This study evaluated the effectiveness of mite penetration of these covers by using the Siriraj chamber method. METHODS Thirty-two covers collected from 9 different countries were categorized accor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2017