SLO radiant power and brightness.
نویسندگان
چکیده
Available output in the Scanning Laser Ophthalmoscope (SLO) may be expressed as radiant power at the beam pivot (SLO exit pupil), in units of microwatts (microW). This power corresponds to dimensions of brightness (like luminance and retinal illuminance) and to a range of related measures (like cd/m2, lm/m2, and the troland value) in both free and Maxwellian views. We demonstrate that the conversion factor power/troland=1.26*10(-3) microW and 3.15*10(-4) microW for SLO nominal visual angles 40 degrees and 20 degrees, respectively. The factor permits measured SLO power to be expressed in units of brightness and (inversely) brightnesses of everyday objects to be expressed in units of SLO power. Examples of both conversions are given. Reference to the literature demonstrates the importance of expressing SLO power in brightness terms common to everyday activities and to visual function-testing instruments besides the SLO.
منابع مشابه
SLO power calibration.
We present a method for calibrating the Scanning Laser Ophthalmoscope (SLO) that predicts radiant power at any of 256 grayscale values (gsv) and 12 polarized filter (polarizer) levels. Predicted power values, p(gsv), were determined by substitution into polynomials linearly transformed to old or new power at p(0) and p(255). This was compared with observed power values at 125 levels of attenuat...
متن کاملThe transscleral VER: normal responses.
Normative data taken on a sample of 10 eyes indicate that transscleral visual evoked response (TVER) stimulation of the cortical evoked response with a range of lights and at lower adaptation levels produces replicable, low-variance responses which may be of sufficient quality for the clinical evaluation of retinal and visual pathway condition. Response amplitudes were related to the radiant pe...
متن کاملPart I Fundamentals
FUNDAMENTALS Part I of our book lays the physical and conceptual foundations of hydrologic optics, the quantitative study of the interactions of light with the earth's oceans, estuaries, lakes, rivers and other water bodies. Radiative transfer theory is the physical and mathematical framework for hydrologic optics. Chapter 1 begins with a few comments upon the nature of light itself and upon th...
متن کاملTime Dilation of BATSE Gamma-ray Bursts
We perform several nonparametric correlation tests on the BATSE 3B data to search for evidence of cosmological time dilation. These tests account for the effects of data truncation due to threshold effects in both limiting brightness and limiting duration, enabling us to utilize a larger number of bursts than in previous analyses. We find little significant evidence for correlation between vari...
متن کاملLarge-field-of-view, modular, stabilized, adaptive-optics-based scanning laser ophthalmoscope.
We describe the design and performance of an adaptive optics retinal imager that is optimized for use during dynamic correction for eye movements. The system incorporates a retinal tracker and stabilizer, a wide-field line scan scanning laser ophthalmoscope (SLO), and a high-resolution microelectromechanical-systems-based adaptive optics SLO. The detection system incorporates selection and posi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of rehabilitation research and development
دوره 38 1 شماره
صفحات -
تاریخ انتشار 2001