An in vivo comparison of gradient and absolute impedance electronic apex locators.
نویسندگان
چکیده
Two electronic apex locators based on the gradient (Apit) and absolute (Odontometer) impedance principles were evaluated. Distances of file tips to apical foramina were determined in vivo with the electronic apex locators and subsequently verified after extraction. Mean differences between file tips and apical foramina were +0.14 +/- 0.27 mm and -0.36 +/- 0.71 mm for the Apit and Odontometer, respectively. These differences were statistically significant (p < 0.001). the Apit's and Odontometer's results ranged from +0.85 to -0.65 mm and from +0.35 to 2.45 mm from the apical foramen, respectively. Ninety-three and 73% of the findings for the Apit and the Odontometer, respectively, were within the +/- 0.5 mm range, whereas 100% and 86%, respectively, were within the +/- 1.0 mm range. Thirty-three and 43% of the results for the Apit and the Odontometer, respectively, were 1.0 mm or less coronal to the apical foramen. The Apit tended to yield the more reliable results because of the narrower range.
منابع مشابه
The effect of different needle-insertion depths on the accuracy of the Root ZX II and Root ZX mini apex locators in the presence of various irrigants
BACKGROUND AND AIM: The aim of the present study was to evaluate the effect of different needle-insertion depths on the accuracy of the Root ZX II and Root ZX mini apex locators in the presence of various irrigants. METHODS: Ninety extracted single-canal human teeth were used in nine experimental groups. The coronal one-third of the canals was preflared, and the length to the major foramen was ...
متن کاملEvaluation of the accuracy of two apex locators in endodontic treatment and retreatments: an ex vivo study
Introduction: Working length determination is important in successful endodontic treatment and retreatment.This study evaluated the accuracy of two electronic apex locators Root ZX and Raypex®6 (EALs) in determining the electronic working length (EWL) of the root canals in endodontic treatment and retreatment. Materials and Methods: Access cavities were prepared on forty extracted, singl...
متن کاملمقایسه دقت دستگاههای اپکس یاب الکترونیکی ZX Root،Novapex در مقایسه با رادیوگرافی در شرایط in vivo
Background and Aims: Working length determination and remaining this length is of great importance in root canal therapy. Recently, electronic apex locators are being used to determine working length and decrease the number of radiographs. The purpose of this study was to compare the sensitivity of Root ZX and Novapex electronic apex locators with radiography in a clinical study. Materials and...
متن کاملEvaluation of the Use of Sixth Generation Apex Locators as a Diagnostic Tool to Detect Root Perforations
Aim: The sixth generation apex locators served as an efficient diagnostic tool for detecting root perforations as these are based on the principle of impedance rather than the conventional gradient method. However, their diagnostic accuracy not evaluated well. In the existing study, we assessed and compared the efficacy of two apex locators for diagnostic perspective. Materials and Methods: A t...
متن کاملIn vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination
In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination Dr. Hasheminia, S.M.* - Dr. Jafari, N.** *Associate Professor of Endodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Dentist. Abstract Background & Aim: Radiography is still the common method of measuring working length in root canal therapy. While, gag refl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of endodontics
دوره 22 5 شماره
صفحات -
تاریخ انتشار 1996