Safety of bioabsorbable implants in vitro
نویسندگان
چکیده
BACKGROUND The aim of the present study was to investigate the safety of bioabsorbable plates and screws in humans. METHODS For this purpose, an implant system based on [poly(lactic-co-glycolic acids)(85:15)] was designed. The system was tested for pH, temperature, and swelling and then its surface morphology was analyzed for surface porosity using environmental electron microscopy. Then, the effects of this bioabsorbable system on the viability and profileration of osteocytes were examined on a molecular level via in vitro experiments. A [poly(lactic-co-glycolic acids)(90:10)] bioabsorbable implant, which is commercially available and used in orthopedic surgery, was used as control group. For the statistical evaluation of the data obtained in the present study, the groups were compared by Tukey HSD test following ANOVA. The significance level was set as p < 0.05. RESULTS It was observed that the osteocytes cultivated on the PLGA system designed in the present study included more live cells and allowed more proliferation compared to the control. CONCLUSION One of the criteria in the selection of implants for orthopedic surgery is that a good implant should not need removal and thus a second surgery. In the present study, a bioabsorbable implant was designed considering this criterion. The present study is the first step to prove the safety of this new design by in vitro toxicity and viability experiments.
منابع مشابه
Adult Stem Cells Properties in Terms of Commitment, Aging and Biological Safety of Grit-Blasted and Acid-Etched Ti Dental Implants Surfaces
Titanium (Ti) is one of the most widely used biomaterials for manufacturing dental implants. The implant surface properties strongly influence osseointegration. The aim of the present study was to in vitro investigate the characteristics of Ti dental implants in terms of mutagenicity, hemocompatibility, biocompatibility, osteoinductivity and biological safety. The Ames test was used to test the...
متن کاملIncidence of infections associated with use of bioabsorbable implants in Orthopedic surgeries
Background: The incidence of placement of osteosynthetic materials has grown worldwide. Bioabsorbable materials are more commonly used now days in Orthopedic surgeries. Implants modify the risk of infection by bacterial adhesion, tissue integration, and immunomodulation. Bacterial adhesion to implant leads to interaction between bacteria and implant. Aim: To evaluate the incidence of infections...
متن کاملAlloys Developed for Bioabsorbable Orthopaedic Implants: A General Review
As a bioabsorbable metal with mechanical properties close to bone, pure magnesium or its alloys have great potential to be developed as medical implants for clinical applications. However, great efforts should be made to degradation rate of pure magnesium or its alloys is one of the focuses in Research and Development (R&D) of medical implants. It has been recognized that surface modification i...
متن کاملPost-sinus surgery insertion of steroid-eluting bioabsorbable intranasal devices: A systematic review.
OBJECTIVES/HYPOTHESIS Postendoscopic sinus surgery corticosteroid administration reduces polyp formation, inflammation, and adhesions. Steroid-eluting bioabsorbable intranasal devices (SEBID) are novel interventions thought to improve local drug delivery while minimizing systemic side effects. The primary aim of this systematic review is to evaluate the efficacy and safety of bioabsorbable SEBI...
متن کاملOsteochondritis Dessicans- Primary Fixation using Bioabsorbable Implants
INTRODUCTION Osteochondritis dessicans (OCD) is a localized condition where a section of articular cartilage and underlying subchondral bone separate from the joint surface. It is important to diagnose unstable OCD early and fix the fragments primarily as the results of any surgical management at late presentations are guarded. Use of bioabsorbable implants for fixing OCD is recent and we repor...
متن کامل