The CT number accuracy of a novel commercial metal artifact reduction algorithm for large orthopedic implants
نویسندگان
چکیده
Philips Healthcare released a novel metal artifact reduction algorithm for large orthopedic implants (O-MAR). Little information was available about its CT number accuracy. Since CT numbers are used for tissue heterogeneity corrections in external beam radiotherapy treatment planning, we performed a phantom study to assess the CT number accuracy of O-MAR. Two situations were simulated: a patient with a unilateral metallic hip prosthesis and a patient with bilateral metallic hip prostheses. We compared the CT numbers in the O-MAR reconstructions of the simulations to those in the nonO-MAR reconstruction and to those in a metal-free baseline reconstruction. In both simulations, the CT number accuracy of the O-MAR reconstruction was better than the CT number accuracy of the nonO- MAR reconstruction. In the O-MAR reconstruction of the unilateral simulation, all CT numbers were accurate within ± 5 HU (AAPM criterion). In the O-MAR reconstruction of the bilateral simulation, CT numbers were found that differed more than ± 5 HU from the metal-free baseline values. However, none of these differences were clinically relevant.
منابع مشابه
Metal Artifact Reduction of Dental Fillings in Head and Neck CT Images
Introduction: The issue of metal artifact and its reduction is as old as the clinical use of computed tomography itself. When metal objects such as dental fillings, hip prostheses or surgical clips are present in the computed tomography (CT) field of view (FOV), make severe artifacts that reduce the image quality and accuracy of CT numbers. They can lead to unreliable ...
متن کاملEvaluation of Metal Artifact Reduction software in Computed Tomography
Introduction: The image quality of computed tomography (CT) can be seriously lowered by metal implants of patients. These implants are known to exert a significant impact on diagnostic accuracy due to artifacts. The current study aimed to assess the usefulness of Metal Artifact Reduction (MAR) software in the reduction of metal artifacts, in comparison to iterative rec...
متن کاملA New Method for Metal Artifact Reduction in CT Scan Images
Introduction In CT imaging, metallic implants inside the tissues cause metal artifact that reduce the quality of image for diagnosis. In order to reduce the effect of this artifact, a new method with more appropriate results has been presented in this research work. Materials and Methods The presented method comprised of following steps: a) image enhancement and metal areas extraction, b) sinog...
متن کاملValue and Clinical Application of Orthopedic Metal Artifact Reduction Algorithm in CT Scans after Orthopedic Metal Implantation
OBJECTIVE To evaluate orthopedic metal artifact reduction algorithm (O-MAR) in CT orthopedic metal artifact reduction at different tube voltages, identify an appropriate low tube voltage for clinical practice, and investigate its clinical application. MATERIALS AND METHODS The institutional ethical committee approved all the animal procedures. A stainless-steel plate and four screws were impl...
متن کاملCT and MRI Techniques for Imaging Around Orthopedic Hardware.
Orthopedic hardware impairs image quality in cross-sectional imaging. With an increasing number of orthopedic implants in an aging population, the need to mitigate metal artifacts in computed tomography and magnetic resonance imaging is becoming increasingly relevant. This review provides an overview of the major artifacts in CT and MRI and state-of-the-art solutions to improve image quality. A...
متن کامل