Biological and biomechanical evaluation of interface reaction at conical screw-type implants

نویسندگان

  • Andre Büchter
  • Ulrich Joos
  • Hans-Peter Wiesmann
  • László Seper
  • Ulrich Meyer
چکیده

BACKGROUND Initial stability of the implant is, in effect, one of the fundamental criteria for obtaining long-term osseointegration. Achieving implant stability depends on the implant-bone relation, the surgical technique and on the microscopic and macroscopic morphology of the implant used. A newly designed parabolic screw-type dental implant system was tested in vivo for early stages of interface reaction at the implant surface. METHODS A total of 40 implants were placed into the cranial and caudal part of the tibia in eight male Göttinger minipigs. Resonance frequency measurements (RFM) were made on each implant at the time of fixture placement, 7 days and 28 days thereafter in all animals. Block biopsies were harvested 7 and 28 days (four animals each) following surgery. Biomechanical testing, removable torque tests (RTV), resonance frequency analysis; histological and histomorphometric analysis as well as ultrastructural investigations (scanning electron microscopy (SEM)) were performed. RESULTS Implant stability in respect to the measured RTV and RFM-levels were found to be high after 7 days of implants osseointegration and remained at this level during the experimented course. Additionally, RFM level demonstrated no alteration towards baseline levels during the osseointegration. No significant increase or decrease in the mean RFM (6029 Hz; 6256 Hz and 5885 Hz after 0-, 7- and 28 days) were observed. The removal torque values show after 7 and 28 days no significant difference. SEM analysis demonstrated a direct bone to implant contact over the whole implant surface. The bone-to-implant contact ratio increased from 35.8 +/- 7.2% to 46.3 +/- 17.7% over time (p = 0,146). CONCLUSION The results of this study indicate primary stability of implants which osseointegrated with an intimate bone contact over the whole length of the implant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of implant/abutment marginal fitting

The success rate of osseointegrated implants is reported to be above 90%. Despite of the knowledge of the mechanisms of osseointegration, some faults still occur at implants systems. Recent researches assign those faults mainly to patient’s prosthetic rehabilitation. The misfit at abutment-implant interface and the missing of a passive adaptation between the prosthesis and the abutment can lead...

متن کامل

The clinical effectiveness of screw type Implant “Nisastan system” in the posterior region of the mandible: A 2 year prospective study

The clinical effectiveness of screw type Implant “Nisastan system” in the posterior region of the mandible: A 2 year prospective study Dr. M. Rismanchian * - Dr. R. Birang ** * Assistant Professor of Fixed Prosthodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Assistant Professor of Periodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences....

متن کامل

Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems

PURPOSE This study evaluated the influence of abutment materials on the stability of the implant-abutment joint in internal conical connection type implant systems. MATERIALS AND METHODS Internal conical connection type implants, cement-retained abutments, and tungsten carbide-coated abutment screws were used. The abutments were fabricated with commercially pure grade 3 titanium (group T3), c...

متن کامل

Comparison of Expansive Pedicle Screw and Polymethylmethacrylate-Augmented Pedicle Screw in Osteoporotic Sheep Lumbar Vertebrae: Biomechanical and Interfacial Evaluations

BACKGROUND It was reported that expansive pedicle screw (EPS) and polymethylmethacrylate-augmented pedicle screw (PMMA-PS) could be used to increase screw stability in osteoporosis. However, there are no studies comparing the two kinds of screws in vivo. Thus, we aimed to compare biomechanical and interfacial performances of EPS and PMMA-PS in osteoporotic sheep spine. METHODOLOGY/PRINCIPAL F...

متن کامل

Multicenter retrospective analysis of the ITI implant system used for single-tooth replacements: results of loading for 2 or more years.

This report involves the retrospective evaluation of ITI implants placed by a group of 12 clinicians located throughout the United States. Of the original 174 single implants placed in 129 patients reported previously, 157 were examined in 110 patients after 2 or more years (average 40.1 months). Twenty-two implants remained in the anterior and 135 implants (86%) remained in the posterior areas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Head & Face Medicine

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2006