Novel Sensor-Enabled Ex Vivo Bioreactor: A New Approach towards Physiological Parameters and Porcine Artery Viability

نویسندگان

  • Raghavendra Mundargi
  • Divya Venkataraman
  • Saranya Kumar
  • Vishal Mogal
  • Raphael Ortiz
  • Joachim Loo
  • Subbu Venkatraman
  • Terry Steele
چکیده

The aim of the present work is to design and construct an ex vivo bioreactor system to assess the real time viability of vascular tissue. Porcine carotid artery as a model tissue was used in the ex vivo bioreactor setup to monitor its viability under physiological conditions such as oxygen, pressure, temperature, and flow. The real time tissue viability was evaluated by monitoring tissue metabolism through a fluorescent indicator "resorufin." Our ex vivo bioreactor allows real time monitoring of tissue responses along with physiological conditions. These ex vivo parameters were vital in determining the tissue viability in sensor-enabled bioreactor and our initial investigations suggest that, porcine tissue viability is considerably affected by high shear forces and low oxygen levels. Histological evaluations with hematoxylin and eosin and Masson's trichrome staining show intact endothelium with fresh porcine tissue whereas tissues after incubation in ex vivo bioreactor studies indicate denuded endothelium supporting the viability results from real time measurements. Hence, this novel viability sensor-enabled ex vivo bioreactor acts as model to mimic in vivo system and record vascular responses to biopharmaceutical molecules and biomedical devices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Sensitive Novel Approach towards the Detection of 8-Hydroxyquinoline at Anionic Surfactant Modified Carbon Nanotube Based Biosensor: A Voltammetric Study

A rapid electrochemical technique was developed to determine 8-Hydroxyquinoline (8HQ). In the current study, the anionic surfactant Sodium lauryl sulfate (SLS) was immobilized on the multi-walled carbon nanotube (MWCNT) paste surface for the fabrication of electrode to detect 8HQ in phosphate buffer solution (PBS) of pH 7.0. The response of SLS modified carbon nanotube paste electrode (SLSMCNTP...

متن کامل

Evaluation of a novel bioartificial liver in rats with complete liver ischemia: treatment efficacy and species-specific alpha-GST detection to monitor hepatocyte viability.

BACKGROUND/AIMS There is an urgent need for an effective bioartificial liver system to bridge patients with fulminant hepatic failure to liver transplantation or to regeneration of their own liver. Recently, we proposed a bioreactor with a novel design for use as a bioartificial liver (BAL). The reactor comprises a spirally wound nonwoven polyester fabric in which hepatocytes are cultured (40 x...

متن کامل

Pushing the Envelope in Tissue Engineering: Ex Vivo Production of Thick Vascularized Cardiac Extracellular Matrix Constructs

Functional vascularization is a prerequisite for cardiac tissue engineering of constructs with physiological thicknesses. We previously reported the successful preservation of main vascular conduits in isolated thick acellular porcine cardiac ventricular ECM (pcECM). We now unveil this scaffold's potential in supporting human cardiomyocytes and promoting new blood vessel development ex vivo, pr...

متن کامل

Development of an Ex Vivo, Beating Heart Model for CT Myocardial Perfusion

OBJECTIVE To test the feasibility of a CT-compatible, ex vivo, perfused porcine heart model for myocardial perfusion CT imaging. METHODS One porcine heart was perfused according to Langendorff. Dynamic perfusion scanning was performed with a second-generation dual source CT scanner. Circulatory parameters like blood flow, aortic pressure, and heart rate were monitored throughout the experimen...

متن کامل

Comparing the Effectiveness of Polymer Debriding Devices Using a Porcine Wound Biofilm Model

Objective: Debridement to remove necrotic and/or infected tissue and promote active healing remains a cornerstone of contemporary chronic wound management. While there has been a recent shift toward less invasive polymer-based debriding devices, their efficacy requires rigorous evaluation. Approach: This study was designed to directly compare monofilament debriding devices to traditional gauze ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2015  شماره 

صفحات  -

تاریخ انتشار 2015