Diffusion-prepared fast imaging with steady-state free precession (DP-FISP): a rapid diffusion MRI technique at 7 T.

نویسندگان

  • Lan Lu
  • Bernadette Erokwu
  • Gregory Lee
  • Vikas Gulani
  • Mark A Griswold
  • Katherine M Dell
  • Chris A Flask
چکیده

Diffusion MRI is a useful imaging technique with many clinical applications. Many diffusion MRI studies have utilized echo-planar imaging (EPI) acquisition techniques. In this study, we have developed a rapid diffusion-prepared fast imaging with steady-state free precession MRI acquisition for a preclinical 7T scanner providing diffusion-weighted images in less than 500 ms and diffusion tensor imaging assessments in ∼1 min with minimal image artifacts in comparison with EPI. Phantom apparent diffusion coefficient (ADC) and fractional anisotropy (FA) assessments obtained from the diffusion-prepared fast imaging with steady-state free precession (DP-FISP) acquisition resulted in good agreement with EPI and spin echo diffusion methods. The mean apparent diffusion coefficient was 2.0 × 10(-3) mm(2) /s, 1.90 × 10(-3) mm(2) /s, and 1.97 × 10(-3) mm(2) /s for DP-FISP, diffusion-weighted spin echo, and diffusion-weighted EPI, respectively. The mean fractional anisotropy was 0.073, 0.072, and 0.070 for diffusion-prepared fast imaging with steady-state free precession, diffusion-weighted spin echo, and diffusion-weighted EPI, respectively. Initial in vivo studies show reasonable ADC values in a normal mouse brain and polycystic rat kidneys.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In-Vivo evaluation of cartilage repair using Steady-State Diffusion Weighted Imaging

Introduction Various MR imaging sequences have given proof of their ability to visualize ultra structural components and to reveal the biochemical composition of cartilage. One encouraging approach in the means of cartilage grading is the use of diffusion weighted sequences [1,2]. Conventional DWI based on spin-echo (SE) sequences is relatively insensitive to susceptibility effects, but diffusi...

متن کامل

Visibility of epidermoid tumors on steady-state free precession images.

PURPOSE To determine whether steady-state free precession sequences improve the MR visibility of epidermoid tumors in comparison with spin-echo images. METHODS Patients were four women and three men with epidermoid tumors in the subarachnoid spaces. MR was performed with a 1.5-T superconductive unit. For steady-state free precession imaging, three-dimensional Fourier transform fast imaging wi...

متن کامل

Diffusion-prepared segmented steady-state free precession: Application to 3D black-blood cardiovascular magnetic resonance of the thoracic aorta and carotid artery walls.

This work developed a three-dimensional (3D) diffusion-prepared segmented steady-steady free precession (DP-SSFP) cardiovascular magnetic resonance (CMR) sequence for black-blood (BB) thoracic aortic and carotid wall visualization. In 14 healthy volunteers, BB CMR of the thoracic aorta (n = 7) and carotid arteries (n = 7) was performed over 12 cm and 3 cm of transversal coverage, respectively, ...

متن کامل

Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm

Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...

متن کامل

In vivo 3D high resolution cardiac diffusion weighted MRI: a motion compensated diffusion-prepared balanced steady-state free precession approach

Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA Full list of author information is available at the end of the article Figure 1 Typical T2 prepared (b = 0 s/mm) images, DWI (b = 450 s/mm) in three orthogonal directions, and ADC maps for M1M2 (top) and TRSE (bottom) diffusion preparation. M1M2 diffusion-prepared images clearly depict myocardium wi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 68 3  شماره 

صفحات  -

تاریخ انتشار 2012