Automatic on line preconcentration and determination of lead in water by ICP-AES using a TS-microcolumn.
نویسندگان
چکیده
A simple, sensitive, low-cost and rapid, flow injection system for the on-line preconcentration of lead by sorption on a microcolumn packed with silica gel funtionalized with methylthiosalicylate (TS-gel) was developped. The metal is directly retained on the sorbent column and subsequently then eluted from it by EDTA. Five variables (sample flow rate, eluent flow rate, eluent concentration, pH and buffer concentration) were considered as factors in the optimization process. Interactions between analytical factors and their optimal levels were investigated using two level factorial and Box-Behnken designs. The optimum conditions established were applied to the determination of lead by flow injection inductively coupled plasma atomic emission spectrometry (FI-ICP-AES). The proposed method has a linear calibration range from 10 to at least 500ngml(-1) of lead. At a sample frequency of 24h(-1) and a 120s preconcentration time, the enrichment factor was 41, the detection limit was 15.3ngml(-1) (S/N=3) and the precision, expressed as relative standard deviation, was 0.9% (at 100ngml(-1)). Validation of the developed method was carried out against electrothermal atomic absorption spectrometry analysis without statistically significant differences between the proposed method and the atomic absorption method.
منابع مشابه
Determination of cadmium in water by ICP-AES with on-line adsorption preconcentration using DPTH-gel and TS-gel microcolumns.
Two flow injection inductively coupled plasma atomic emission spectrometric methods for the preconcentration and determination of trace amounts of cadmium in sea-water and waste-water samples are described based on the adsorption of the metal ion on a micro-column placed in the injection valve of the FI manifold and packed with silica gel funtionalised with 1,5-bis(di-2-pyridyl) methylene thioc...
متن کاملDetermination of cobalt in urine by FI-ICP-AES with online preconcentration.
A method for the preconcentration and determination of cobalt in human urine samples was developed. The online preconcentration and determination were attained using inductively coupled plasma atomic emission spectromety (ICP-AES) coupled to a flow injection (FI) method. Cobalt was retained on an Amberlite XAD-7 resin as cobalt-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol complex at pH 9.5. Co...
متن کاملApplication of iminodiacetate chelating resin muromac A-1 in on-line preconcentration and inductively coupled plasma optical emission spectroscopy determination of trace elements in natural waters
On-line system incorporating a microcolumn of Muromac A-1 resin was used for the developing of method for preconcentration of trace elements followed by inductively coupled plasma (ICP) atomic emission spectrometry determination. A chelating type ion exchange resin has been characterized regarding the sorption and subsequent elution of 24 elements, aiming to their preconcentration from water sa...
متن کاملOn-line preconcentration and determination of cobalt by DPTH-gel chelating microcolumn and flow injection inductively coupled plasma atomic emission spectrometry.
This paper reports the development of a new methodology for the determination of cobalt in biological samples by using a flow injection system with loaded DPTH-gel as solid phase to preconcentrate analytes. The procedure is based on the on-line preconcentration of cobalt on a microcolumn of 1,5-bis(di-2-pyridyl)methylene thiocarbohydrazide immobilized on silica gel (DPTH-gel). The trapped cobal...
متن کاملSelective Separation and Preconcentration of trace Amounts of Gallium in Water and Rice Samples using Cloud Point Extraction and Determination by Inductively Coupled Plasma-Atomic Emission Spectrometry
In the present study a cloud-point extraction process using non-ionic surfactant Triton X-114 for selective extraction of gallium from aqueous solutions was developed. The method is based on the complex formation of Ga (III) with N, N′ -bis (salycilidene)-1, 2-phenylenediamine (salophen) as a chelating agent in buffer media of pH 5. After phase separation and dilution of the surfactant-rich pha...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Talanta
دوره 62 3 شماره
صفحات -
تاریخ انتشار 2004