Cutaneous Legionella longbeachae Infection in Immunosuppressed Woman, United Kingdom
نویسندگان
چکیده
We report a rare case of cutaneous Legionella longbeachae infection in a patient receiving long-term corticosteroids for immune thrombocytopenia. Such infections cannot be identified by using Legionella urinary antigen testing but are commonly seen after exposure to commercial potting compost, particularly in immunocompromised patients.
منابع مشابه
Distribution of Legionella longbeachae serogroup 1 and other legionellae in potting soils in Australia.
Legionella longbeachae serogroup 1 and other Legionella spp. were isolated from 73% of 45 potting soils made in Australia by 13 manufacturers but were not detected in 19 potting soils made in Greece, Switzerland, and the United Kingdom examined between March 1989 and May 1990. Several Legionella species were isolated from a small number of samples of uncomposted pine sawdusts, but it is not kno...
متن کاملARDS with septic shock due to Legionella longbeachae pneumonia in a patient with polymyalgia rheumatica
Legionella longbeachae is a very uncommon cause of community acquired pneumonia in Western countries. L. longbeachae does not grow on blood agar media and is usually not detected by sputum gram stain or blood culture. Furthermore Legionella urinary antigen testing fails to detect it. In this report we described a 79-year-old man with polymyalgia rheumatica under systemic corticosteroid treatm...
متن کاملGenetic susceptibility and caspase activation in mouse and human macrophages are distinct for Legionella longbeachae and L. pneumophila.
Legionella pneumophila is the predominant cause of Legionnaires' disease in the United States and Europe, while Legionella longbeachae is the common cause of the disease in Western Australia. Although clinical manifestations by both intracellular pathogens are very similar, recent studies have shown that phagosome biogeneses of both species within human macrophages are distinct (R. Asare and Y....
متن کاملPopulation Genomics of Legionella longbeachae and Hidden Complexities of Infection Source Attribution
Legionella longbeachae is the primary cause of legionellosis in Australasia and Southeast Asia and an emerging pathogen in Europe and the United States; however, our understanding of the population diversity of L. longbeachae from patient and environmental sources is limited. We analyzed the genomes of 64 L. longbeachae isolates, of which 29 were from a cluster of legionellosis cases linked to ...
متن کاملInfection of Tetrahymena pyriformis by Legionella longbeachae and other Legionella species found in potting mixes.
All Legionella longbeachae strains, both serogroups of L. bozemanii, and three strains of L. anisa reproducibly infected washed Tetrahymena pyriformis at 30 degrees C. L. pneumophila serogroup 1 strains infected T. pyriformis less reproducibly than did L. longbeachae. Low-level concentrations of nutrients in cocultures inhibited infection. Four L. micdadei strains and L. anisa ATCC 35292 failed...
متن کامل