Reliable LIF/Mie droplet sizing in sprays using structured laser illumination planar imaging.

نویسندگان

  • Yogeshwar Nath Mishra
  • Elias Kristensson
  • Edouard Berrocal
چکیده

In this article, Structured Laser Illumination Planar Imaging (SLIPI) is used in combination with the LIF/Mie ratio technique for extracting a reliable two-dimensional mapping of the droplets Sauter Mean Diameter (SMD). We show that even for the case of a fairly dilute spray, where single scattering events are in majority, the conventional LIF/Mie technique still remains largely affected by errors introduced by multiple light scattering. To remove this unwanted light intensity on both the LIF and Mie images SLIPI is used prior to apply the image ratio. For the first time, the SLIPI LIF/Mie results are calibrated and compared with measurement data from Phase Doppler Interferometry (PDI).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Planar droplets sizing of a hollow-cone spray using SLIPI-LIF/MIE

In this work, we report an original experimental approach for measuring the two-dimensional distribution of the droplets Sauter Mean Diameter (SMD) using the SLIPI-LIF/MIE technique. A hollow-cone spray is formed by continuously injecting water mixed with a non-toxic fluorescing dye at 20 bars injection pressure. The spray is illuminated using a continuous wave laser. The illumination wavelengt...

متن کامل

Application of structured illumination for multiple scattering suppression in planar laser imaging of dense sprays.

A novel approach to reduce the multiple light scattering contribution in planar laser images of atomizing sprays is reported. This new technique, named Structured Laser Illumination Planar Imaging (SLIPI), has been demonstrated in the dense region of a hollow-cone water spray generated in ambient air at 50 bars injection pressure. The idea is based on using an incident laser sheet which is spat...

متن کامل

Qualitative measurements of pressure-atomized sprays through simultaneous collection of planar fluorescence, phosphorescence, and Mie scattering data

A laser diagnostic technique useful for qualitatively locating and describing regions of vapor and liquid structures of a pressure atomized fuel spray is examined. While Mie scattering is sensitive to the liquid phase within a spray, planar laser-induced fluorescence is sensitive to both the liquid and vapor phases. Hence, a comparison of images utilizing these two techniques could be used to q...

متن کامل

Attenuation effects on imaging diagnostics of hollow-cone sprays.

Detrimental effects to quantitative interpretation of Mie and laser-induced fluorescence images of hollow-cone sprays were investigated. The attenuation of the laser beam leads to locally unknown intensities rendering it impossible to obtain high-fidelity images of these sprays. Two strategies that use bidirectional illumination of the spray are discussed and evaluated. Conditions for which a b...

متن کامل

Compensation method for attenuated planar laser images of optically dense sprays.

We present a method for compensating laser attenuation in optically dense sprays, in particular for use in combustion engine research. Images of the fuel sprays are produced by planar laser imaging, where Mie scattered light from a cross section of the spray is imaged onto a CCD camera. The compensation scheme is based on the Beer-Lambert law, which is used here to sum up the loss of light alon...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics express

دوره 22 4  شماره 

صفحات  -

تاریخ انتشار 2014