Using a quartz crystal microbalance for low energy ion beam etching studies

نویسندگان

  • M. F. Doemling
  • B. Lin
  • N. R. Rueger
  • G. S. Oehrlein
  • R. A. Haring
  • Y. H. Lee
چکیده

A quartz crystal microbalance ~QCM! has been used for etching yield measurements in a low energy ion beam system. The goal is to obtain etching yields for ion energies below 150 eV for various ion chemistries and target materials. Typical beam currents are about 0.5 mA, and the mass change per unit time on the QCM is much smaller than that for typical QCM applications. A number of problems with the application of a QCM were encountered and a description of how they were overcome is presented in this article. Quantitative etch yield results for the etching of two different photoresists and SiO2 down to 25 eV ion energy are presented. © 2000 American Vacuum Society. @S0734-2101~00!04101-4#

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sputtering yield measurements at glancing incidence using a quartz crystal microbalance

Low energy sputtering yields at grazing incidence have been investigated experimentally using a quartz crystal microbalance QCM technique. This method involved precoating the QCM with a thin film of the desired target material and relating the resonance frequency shift directly to mass loss during ion bombardment. A highly focused, low divergence ion beam provided a well defined incidence angle...

متن کامل

Quartz crystal microbalance-based system for high-sensitivity differential sputter yield measurements.

We present a quartz crystal microbalance-based system for high sensitivity differential sputter yield measurements of different target materials due to ion bombardment. The differential sputter yields can be integrated to find total yields. Possible ion beam conditions include ion energies in the range of 30-350 eV and incidence angles of 0 degrees-70 degrees from normal. A four-grid ion optics...

متن کامل

Total and Differential Sputter Yields of Boron Nitride Measured by Quartz Crystal Microbalance

We present differential sputter yield measurements of boron nitride due to bombardment by xenon ions. A four-grid ion optics system is used to achieve a collimated ion beam at low energy (<100 eV). A quartz crystal microbalance (QCM) is used to measure differential sputter yield profiles of condensable components from which total sputter yields can also be determined. We report total and differ...

متن کامل

C60 molecular depth profiling of a model polymer

The bombardment of a 26 nm poly(methyl methacrylate) (PMMA) film has been studied as a model for depth profiling of polymeric samples using a newly developed C60 þ ion source. Experiments were conducted on a ToF-SIMS instrument equipped with C60 þand Gaþ ion sources. A focused dc C60 þ ion beam was used to etch through the polymer sample at specified time intervals. Subsequent spectra were reco...

متن کامل

Investigation of Early Nucleation Events in Magnesium Oxide During Ion Beam Assisted Deposition

Ion beam assisted deposition (IBAD) is used to biaxially texture magnesium oxide (MgO), which is useful as a template for the heteroepitaxial growth of various thin film devices and most notably as a template layer for high temperature superconductors. Improvements in the quality of IBAD MgO films have been largely empirical and there is uncertainty as to the exact mechanism by which this biaxi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999