Nubac Disc Arthroplasty: Preclinical Studies and Preliminary Safety and Efficacy Evaluations

نویسندگان

  • Qi-Bin Bao
  • Matthew Songer
  • Luis Pimenta
  • Dieter Werner
  • Alejandro Reyes-Sanchez
  • Massimo Balsano
  • Umberto Agrillo
  • Domagoj Coric
  • Kenneth Davenport
  • Hansen Yuan
چکیده

BACKGROUND Disc arthroplasty is gaining popularity for treatment of low-back pain caused by degenerative disc disease (DDD). It can involve total disc replacement or partial disc or nucleus replacement (or augmentation). Compared with total disc replacement, nucleus replacement is less invasive, has less surgical risk, has faster postoperative recovery, and doesn't "burn bridges" should further surgery be required. However, nucleus replacement has a high risk of implant expulsion because the device is not fixed to the vertebrae. Nubac is the first polyetheretherketone (PEEK)-on-PEEK articulated disc arthroplasty device designed to optimally restore the lumbar anatomy and biomechanics. METHODS ISO 10993 standards were used to evaluate the biocompatibility of the PEEK material. Chemical and thermal-mechanical tests and in vivo study assessed PEEK's biostability after exposure to high g irradiation and harsh oxidative conditions. Biomechanical tests to evaluate kinematic properties and anatomical restoration of the implanted lumbar motion segments and implant expulsion risk assessments were performed with a human cadaveric model. Because of the novelty of PEEK-on-PEEK as a self-mating articulating material, extensive wear tests were conducted with unidirectional and coupled motions. Static and fatigue strength also were tested. Animal study with a baboon model was conducted with gross, radiographic, biomechanical, and histological evaluations at 6 and 12 months postoperatively. Preliminary clinical data were collected through a prospective multicenter cohort study. RESULTS PEEK demonstrated exceptional biocompatibility and biodurability. Nubac restored disc height and motion segment range of motion. The unique articulating design of the Nubac demonstrated low risk of implant expulsion in a human cadaveric model. Wear tests showed that the Nubac has minimal wear and compares favorably to other disc arthroplasty materials. The Nubac also had excellent static and fatigue properties for the intended application. The animal study showed that the Nubac caused no adverse local or systematic tissue reaction and there was no detectable wear debris. The preliminary clinical data showed no major intraoperative vascular and neurological complications. There was significant Visual Analog Scale and Oswestry Disability Index score improvement. CONCLUSIONS The preclinical data supported the design rationale, and the preliminary clinical data (level II evidence) on safety and efficacy were encouraging. CLINICAL RELEVANCE The Nubac could be a viable first surgical option for patients with back pain caused by DDD.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tranexamic Acid in Total Joint Arthroplasty: Efficacy and Safety

  Despite improvements in surgical and anesthetic techniques, total joint arthroplasty (TJA) is still associated with substantial blood loss and postoperative anemia (1). A considerable portion of patients with postoperative anemia require blood transfusion, which has been shown to negatively affect the outcome of TJA and predisposes patients to development of surgical site infection and peripr...

متن کامل

Experimental Evaluations of Intervertebral Disc Mechanics Following Posterolateral Fusion are Dependent on Testing Protocol

IntroductionNumerous studies have sought to quantify the biomechanical effects of posterior spinal fusion and disc arthroplasty; however, the results from these studies are conflicting. Additionally, the variety of techniques utilized during biomechanical testing complicates comparing results of instrumentation studies. Two distinct methods of experimental loading protocols have emerged to test...

متن کامل

Arthroplasty versus fusion for single-level cervical disc disease.

OBJECTIVE To evaluate the effectiveness and safety of cervical arthroplasty and anterior cervical discectomy fusion methods. METHODS The randomised clinical trial was conducted at the neurosurgical clinic of University of Harran, Turkey, between February 2009 and January 2010. The patients had single level disc disorder between C4-C7 levels. Before surgery, all of the patients had taken medic...

متن کامل

استفاده از پلاسمای غنی از پلاکت در بازسازی دیسک بین مهره ای: مروری بر مطالعات پیش بالینی و آزمایشات بالینی

Intervertebral disc degeneration (IDD) is a prevalent disease that usually starts from the third decade of life and it is considered as one of the reasons contributing to social and economic problems. The results of several studies have shown that platelet-rich plasma (PRP) has the ability to stimulate cell growth and proliferation of extracellular matrix. However, studies for IDD have so far m...

متن کامل

Intradiscal Injection of Autologous Platelet-Rich-Plasma for the Treatment of Lumbar Disc Degeneration -Preliminary Prospective Clinical Trial for Discogenic Low Back Pain Patients-

INTRODUCTION: Intervertebral disc (IVD) degeneration is an important clinical problem that often contributes to low back pain and degenerative disc diseases. Degeneration of the IVD induces anulus tears and fissures, which can cause severe discogenic low back pain. Because the IVD has little potential to self-regenerate, treatment of degenerative disc disease is one of the most challenging clin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2007