Design of an Anthropomorphic Intensity Modulated Radiation Therapy Quality Assurance Phantom

نویسندگان

  • Dee-Ann Radford
  • David S. Followill
  • Peter A. Balter
  • William F. Hanson
  • M. D. Anderson
چکیده

The dynamic nature of IMRT delivery poses unique problems relating to the accurate and reproducible quality assurance of dose delivery. The usefulness of point detectors is limited to static fields and regions within low dose-gradients for treatment verification. However, dose distributions generated in intensity modulated radiation therapy (IMRT) often have complex shapes with high dose gradient regions surrounding critical patient structures. Currently, there is no standardized tool for evaluating IMRT treatment delivery. As part of its commitment to the Advanced Technology Consortium, the Radiation Physics Center (RPC) is developing an anthropomorphic quality assurance phantom for the purpose of reviewing IMRT treatment modalities at institutions participating in future NCI cooperative clinical trials. The phantom will verify the ability of institutions to meet the criteria for field localization and three-dimensional dose delivery for IMRT treatments. Specifically, the design of the phantom will allow the measurement of target dose homogeneity to within 5%, field localization for high dose-gradient regions to within 2mm, and absolute dose to isocenter to within 5%. In this poster we present the development of a quality assurance tool for use in the verification of IMRT delivery modalities used in dose-escalated conformal therapy of the prostate. These treatment modalities include the MIMiC arc delivery system, dynamic MLC, and compensators.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comprehensive end-to-end test for intensity-modulated radiation therapy for nasopharyngeal carcinoma using an anthropomorphic phantom and EBT3 film

Background: In head and neck radiotherapy, immobilization devices can affect dose delivery. In this study, a comprehensive end-to-end test was developed to evaluate the accuracy of radiotherapy treatment. Materials and Methods: An Alderson Radiation Therapy (ART) anthropomorphic phantom with EBT3 film was used to mimic the actual patient treatment process. Ten patients treated for nasopharyngea...

متن کامل

Design and implementation of an anthropomorphic quality assurance phantom for intensity-modulated radiation therapy for the Radiation Therapy Oncology Group.

PURPOSE To design, construct, and evaluate an anthropomorphic phantom for evaluation of intensity-modulated radiation therapy (IMRT) dose planning and delivery, for protocols developed by the Radiation Therapy Oncology Group (RTOG) and other cooperative groups. METHODS AND MATERIALS The phantom was constructed from a plastic head-shaped shell and water-equivalent plastics. Internal structures...

متن کامل

Three-dimensional gel dosimetry for dose volume histogram verification in compensator-based IMRT

Background: Some tissues in human body are radiobiologically different from water and these inhomogeneity must be considered in dose calculation in order to achieve an accurate dose delivery. Dose verification in complex radiation therapy techniques, such as intensity‐modulated radiation therapy (IMRT) calls for volumetric, tissue equivalent and energy independent dosimeter. The purpose of this...

متن کامل

Feasibility of a 3D-printed anthropomorphic patient-specific head phantom for patient-specific quality assurance of intensity-modulated radiotherapy

This study evaluated the feasibility of utilizing a 3D-printed anthropomorphic patient-specific head phantom for patient-specific quality assurance (QA) in intensity-modulated radiotherapy (IMRT). Contoured left and right head phantoms were converted from DICOM to STL format. Fused deposition modeling (FDM) was used to construct an anthropomorphic patient-specific head phantom with a 3D printer...

متن کامل

Design, development, and implementation of the radiological physics center's pelvis and thorax anthropomorphic quality assurance phantoms.

The Radiological Physics Center (RPC) developed two heterogeneous anthropomorphic quality assurance phantoms for use in verifying the accuracy of radiation delivery: one for intensity-modulated radiation therapy (IMRT) to the pelvis and the other for stereotactic body radiation therapy (SBRT) to the thorax. The purpose of this study was to describe the design and development of these two phanto...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000