Skin Impedance Measurements for Acupuncture Research: Development of a Continuous Recording System
نویسندگان
چکیده
Skin impedance at acupuncture points (APs) has been used as a diagnostic/therapeutic aid for more than 50 years. Currently, researchers are evaluating the electrophysiologic properties of APs as a possible means of understanding acupuncture's mechanism. To comprehensively assess the diagnostic, therapeutic and mechanistic implications of acupuncture point skin impedance, a device capable of reliably recording impedances from 100 kOmega to 50 MOmega at multiple APs over extended time periods is needed. This article describes design considerations, development and testing of a single channel skin impedance system (hardware, control software and customized electrodes). The system was tested for accuracy against known resistors and capacitors. Two electrodes (the AMI and the ORI) were compared for reliability of recording over 30 min. Two APs (LU 9 and PC 6) and a nearby non-AP site were measured simultaneously in four individuals for 60 min. Our measurement system performed accurately (within 5%) against known resistors (580 kOmega-10 MOmega) and capacitors (10 nF-150 nF). Both the AMI electrode and the modified ORI electrode recorded skin impedance reliably on the volar surface of the forearm (r = 0.87 and r = 0.79, respectively). In four of four volunteers tested, skin impedance at LU 9 was less than at the nearby non-AP site. In three of four volunteers skin impedance was less at PC 6 than at the nearby non-AP site. We conclude that our system is a suitable device upon which we can develop a fully automated multi-channel device capable of recording skin impedance at multiple APs simultaneously over 24 h.
منابع مشابه
Biomedical engineering meets acupuncture - development of a miniaturized 48-channel skin impedance measurement system for needle and laser acupuncture
BACKGROUND Due to controversially discussed results in scientific literature concerning changes of electrical skin impedance before and during acupuncture a new measurement system has been developed. METHODS The prototype measures and analyzes the electrical skin impedance computer-based and simultaneously in 48 channels within a 2.5×3.5 cm matrix. Preliminary measurements in one person were ...
متن کاملDevelopment and evaluation of a novel four-electrode device system for monitoring skin impedance.
Qi, meridians, and acupoints are important issues in Chinese medicine. One of the theories claims that acupuncture points and meridians have unique electrical properties. The associations between acupuncture points or meridians and special electrical properties are still under debate. In the current study, we introduced and explained a device for this kind of research and evaluated the reliabil...
متن کاملقلب نگاری امپدانسی روشی برای پایش غیرتهاجمی حجم ضربه ای: یک مطالعه ی مقدماتی
Abstract Background: Impedance cardiography (ICG) is a simple and inexpensive technique for non-invasive and continues measurement of stroke volume. Due to non-invasive nature, ICG is becoming increasingly used in research and clinical applications. With regard to lack of domestic impedance cardiograph and limited similar imported products in the country, an inexpensive and portable protot...
متن کاملAn active electrode for biopotential recording from small localized bio-sources
BACKGROUND Laser bio-stimulation is a well-established procedure in Medical Acupuncture. Nevertheless there is still a confusion as to whether it works or the effect is just placebo. Although a plethora of scientific papers published, showing positive clinical results, there is still a lack of objective scientific proofs about the bio-stimulation effect of lasers used in Acupuncture. The object...
متن کاملElectrical skin impedance at acupuncture points.
OBJECTIVES To test whether electrical skin impedance at each of three acupuncture points (APs) is significantly lower than at nearby sites on the meridian (MP) and off the meridian (NP). DESIGN Two instruments - Prognos (MedPrevent GmbH, Waldershof, Germany), a constant-current (DC) device, and PT Probe (designed for this study), a 100-Hz sinusoidal-current (AC) device-were used to record ele...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Evidence-based Complementary and Alternative Medicine : eCAM
دوره 5 شماره
صفحات -
تاریخ انتشار 2008