For detection of cardiac ischemia based on regional pCO2 measurement, sensor drift becomes a problem when monitoring over several hours. A real-time drift correction algorithm was developed based on utilization of the time-derivative to distinguish between physiological responses and the drift, customized by measurements from a myocardial infarction porcine model (6 pigs, 23 sensors). IscAlertTM conductometric pCO2 sensors were placed in the myocardial regions supplied by the left anterior descending coronary artery (LAD) and the left circumflex artery (LCX) while the LAD artery was fully occluded for 1, 3, 5 and 15 min leading to ischemia in the LADdependent region. The measured pCO2, the drift-corrected pCO2 ( pCO2) and its time-derivative (TDpCO2) were compared with respect to detection ability. Baseline stability in the pCO2 led to earlier, more accurate detection. The TDpCO2 featured the earliest sensitivity, but with a lower specificity. Combining pCO2 and TDpCO2 enables increased accuracy. Suggestions are given for the utilization of the parameters for an automated early warning and alarming system. In conclusion, early detection of cardiac ischemia is feasible using the conductometric pCO2 sensor together with parameterization methods.
منابع مشابه
A novel biomedical sensor for early detection of organ ischemia
Measuring PCO2 (partial pressure of carbon dioxide) in an organ can enableearly detection of ischemia. However, there are few clinical applicablesolutions for measuringPCO2. Based upon the requirement for clinicalapplications, a conductivity based PCO2 sensor is proposed. A conductivitybased PCO2 sensor measures conductance in an aqueous solution separatedfrom the me...
متن کاملA Conductometric Urea Biosensor by Direct Immobilization of Urease on Pt Electrode
Urease was immobilized on platinum electrode both by chemical binding and electropolymerization.The conductometric urea biosensor thus prepared showed a detection limit of 4.9×10-5 M and linear dynamic range from 4.9×10-5 to 5.8×10-3 M for urea concentration when the enzyme is covalently immobilized on Pt electrodes. Conductometric transducers respo...
متن کاملA new biomedical sensor for measuring PCO2.
Measuring PCO2 (partial pressure of carbon dioxide) in an organ can enable early detection of ischemia. However, there are few clinical applicable solutions for measuring PCO2. Based upon the requirement for clinical applications, a conductivity based PCO2 sensor is proposed. A conductivity based PCO2 sensor measures conductance in an aqueous solution separated from the measured object by a gas...
متن کاملDesign and fabrication of a rapid conductometric pH sensor based on metal-oxide technology
A micro-fabricated metal-oxide based conductometric pH sensor is designed and fabricated in this manuscript. pH sensors have applications in various areas from farming to food processing, human health monitoring, industrial waste products investigation, etc. Accordingly, there is a relatively high demand for a reliable, rapid and precise pH sensor in the market. Relatively precise pH sensors ha...
متن کاملConductometric Soot Sensor for Automotive Exhausts: Initial Studies
In order to reduce the tailpipe particulate matter emissions of Diesel engines, Diesel particulate filters (DPFs) are commonly used. Initial studies using a conductometric soot sensor to monitor their filtering efficiency, i.e., to detect a malfunction of the DPF, are presented. The sensors consist of a planar substrate equipped with electrodes on one side and with a heater on the other. It is ...
متن کامل