Standardization of C-peptide measurements.
نویسندگان
چکیده
BACKGROUND C-peptide is a marker of insulin secretion in diabetic patients. We assessed within- and between-laboratory imprecision of C-peptide assays and determined whether serum calibrators with values assigned by mass spectrometry could be used to harmonize C-peptide results. METHODS We sent 40 different serum samples to 15 laboratories, which used 9 different routine C-peptide assay methods. We also sent matched plasma samples to another laboratory for C-peptide analysis with a reference mass spectrometry method. Each laboratory analyzed 8 of these samples in duplicate on each of 4 days to evaluate within- and between-day imprecision. The same 8 samples were also used to normalize the results for the remaining samples to the mass spectrometry reference method. RESULTS Within- and between-run CVs ranged from <2% to >10% and from <2% to >18%, respectively. Normalizing the results with serum samples significantly improved the comparability among laboratories and methods. After normalization, the differences among laboratories in mean response were no longer statistically significant (P = 0.24), with least-squares means of 0.93-1.02. CONCLUSIONS C-peptide results generated by different methods and laboratories do not always agree, especially at higher C-peptide concentrations. Within-laboratory imprecision also varied, with some methods giving much more consistent results than others. These data show that calibrating C-peptide measurement to a reference method can increase comparability between laboratories.
منابع مشابه
Effect of Antenatal Dexamethasone on Serum Umbilical Cord C-peptide and Glucose Levels in Term Neonates Delivered by elective Cesarean Section
Background: Antenatal steroid therapy recently has been considered for term and late preterm neonates delivered by Cesarean section (CS), with the aim of preventing adverse respiratory morbidity. The main aim of this study was to investigate the metabolic effects of antenatal dexamethasone on blood glucose (BG), homeostasis, and serum C-peptide level when administered to term fetuses. Methods: ...
متن کاملFeasibility of standardization of serum C-peptide immunoassays with isotope-dilution liquid chromatography-tandem mass spectrometry.
BACKGROUND Serum C-peptide concentrations reflect pancreatic function in different clinical and diagnostic settings; however, the utility of C-peptide testing is limited by the lack of standardized commercial immunoassays. Standardization can best be done by split-sample comparison with a hierarchically higher reference measurement procedure with a set of native sera. For serum peptides, isotop...
متن کاملComparative assessment of N-terminal pro-B-type natriuretic peptide, nitric oxide and echocardiography for diagnosis of dilated cardiomyopathy in dogs
The aim of the study was to evaluate the clinical usefulness of N-terminal pro-brain natriuretic peptide (NT-Pro BNP) and nitric oxide (NO) with echocardiography (gold standard test) in diagnosis of canine cardiomyopathy. Out of 374 cases, 82 cases showing cardiovascular abnormalities including 16 cases of cardiomyopathy were further selected for standardization of biomarkers. Significant (P
متن کاملSynthesis of nocistatin C-terminal and it’s amide derivatives as an opioid peptide
A new biological active hexapeptide of C-terminal of nocistatin, contains Glu-Gln-Lys-Gln-Leu-Gln sequence was synthesized according to solid phase peptide synthesis on the surface of 2-chloro tritylchloride resin and using fmoc-protected amino acids in the presence of TBTU (O-(Benzotriazol-1-yl)-N,N,N',N'-tetramethyl uranium tetrafluoroborate) as a coupling reagent. Then, amidation of the C-te...
متن کاملبررسی ارتباط پپتید-C و انسولین مایع آمنیوتیک با ماکروزومی نوزادان
Background: Fetal hyperinsulinemia correlated with large birth weight and impaired glucose tolerance test and obesity in second decades of life. In this study we compared the correlation between fetal insulin production (as estimated by amniotic fluid (AF) C-peptide concentration) and AF insulin with macrosomia (as estimated by neonatal birth weight 4000 gr).Methods: Thirty eight neonates were...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 54 6 شماره
صفحات -
تاریخ انتشار 2008