The Assessment of Reliability of Cognitive Evoked Potential in Normal Person

نویسندگان

  • Ji Seong Hong
  • Ji Hoon Lee
  • Yeo Hoon Yoon
  • Jung Hwa Choi
  • Jae Eun Shin
  • Sun Mi Kim
  • Yoon Ghil Park
چکیده

OBJECTIVE To evaluate intra-tester reliability of P300 more precisely, this study was designed. Event-related potential (ERP) is the result of endogenous brain response following cognitive stimulus. The P300 component of the human ERP is a positive wave with a latency of 300 ms or greater. Our purpose of this study was to estimate reliability of P300 latency and amplitude with 30 normal persons without head injury, as well as to set up them as the reference values in the event that they would be found to be highly reliable. METHODS ERP was performed at three separate times on 30 normal adults in their 20s and 30s. We measured P300 latency and amplitude among ERP. RESULTS P300 latency show excellent reliability with intraclass correlation coefficient (ICC) of 0.81. As to P300 amplitude, reliability was good to fair with ICC of 0.53. Average value of P300 latency was 311.3±37.0 ms, shorter than reference value of previous study in Korea. CONCLUSION P300 latency revealed higher reliability than P300 amplitude, although reliability of P300 was confirmed in both component. After further study including precise mechanism, influence factor on measurement and method standardization, it is expected to be an objective indicator to assess the cognitive state and predict prognosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of visual evoked potential changes in patients with alzheimer, vascular dementia and minimal cognitive Impairment with healthy people: a case-control study

Background: Alzheimer dementia as the most common cause of dementia is a chronic, progressive, irreversible and incurable disease. The second most common cause of dementia after Alzheimer is vascular dementia. One of the systems involved in dementia is the visuospatial system and visual evoked potential (VEP) can be one of the diagnostic methods for this disease. Therefore, the present study ai...

متن کامل

Reliability of Motor Evoked Potentials Induced by Transcranial Magnetic Stimulation: The Effects of Initial Motor Evoked Potentials Removal

Introduction: Transcranial magnetic stimulation (TMS) is a useful tool for assessment of corticospinal excitability (CSE) changes in both healthy individuals and patients with brain disorders. The usefulness of TMS-elicited motor evoked potentials (MEPs) for the assessment of CSE in a clinical context depends on their intra-and inter-session reliability. This study aimed to evaluate if removal ...

متن کامل

Comparison of the Wave Amplitude of Visually Evoked Potential in Amblyopic Eyes between Patients with Esotropia and Anisometropia and a Normal Group

Background: We compared the wave amplitude of visually evoked potential (VEP) between patients with esotropic and anisometropic amblyopic eyes and a normal group.Methods: The wave amplitude of VEP was documented in 2 groups of persons with amblyopia (15 with esotropia and 28 with anisometropia) and 1 group of individuals with normal visual acuity (n, 15). The amplitude of P100 was recorded mono...

متن کامل

The Effect of Cognitive Tasks on the Ocular Vestibular Evoked Myogenic Potentials in Healthy People

Introduction: The majority of the daily life activities involve the concurrent performance of simultaneously challenging motor and cognitive activities, such as talking while walking, which requires the vestibular system for balance. Functional balance allows the brain to interpret and integrate the sensory information from our physical and social environment. This study aimed to investig...

متن کامل

Machine learning based Visual Evoked Potential (VEP) Signals Recognition

Introduction: Visual evoked potentials contain certain diagnostic information which have proved to be of importance in the visual systems functional integrity. Due to substantial decrease of amplitude in extra macular stimulation in commonly used pattern VEPs, differentiating normal and abnormal signals can prove to be quite an obstacle. Due to developments of use of machine l...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 37  شماره 

صفحات  -

تاریخ انتشار 2013