Intraoperative color Doppler ultrasound assessment of LIMA-to-LAD anastomoses in off-pump coronary artery bypass grafting.
نویسندگان
چکیده
BACKGROUND Although techniques for off-pump coronary artery bypass grafting (CABG) are continually being refined, angiographic follow-up studies have indicated a higher rate of anastomoses-related stenoses than expected after traditional on-pump CABG. This study was performed to evaluate the use of intraoperative epicardial color Doppler ultrasound to quality-assess left internal mammary artery (LIMA) to left anterior descending coronary artery (LAD) anastomoses performed on the beating heart. METHODS Twenty-four LIMA-to-LAD anastomoses were evaluated with real-time epicardial ultrasound imaging using an ultrasound transducer positioned between the paddles of the stabilizer during off-pump procedures. The length of the anastomosis (D(A)), diameters of LIMA (D(M)), LAD at the toe of the anastomosis (D1), and 5 mm distally to the anastomosis (D2) were measured, and the ratios between these variables were calculated. The flow velocity through the anastomoses was visualized by color Doppler coding, and flow was assessed with transit-time flowmetry. RESULTS The epicardial color Doppler ultrasound allowed accurate assessment of the anastomoses. Twenty-three (96%) of the primary anastomoses were confirmed as patent. Mean ratios of D1/D2, D(A)/D2, and D(M)/D2 were 0.89 +/- 0.13, 3.01 +/- 1.04 and 1.32 +/- 0.32, respectively. One anastomosis had a stenosis more than 50% detected by color Doppler ultrasound. After surgical revision, transit-time flow increased from 22 to 40 ml/min. CONCLUSIONS Intraoperative color Doppler ultrasound allowed adequate imaging for quality assessment of LIMA-to-LAD anastomoses performed on the beating heart. One anastomosis was revised due to a technical error detected by epicardial color Doppler imaging. Epicardial ultrasound scanning is a valuable tool for intraoperative assessment of LIMA-to-LAD anastomoses during off-pump coronary surgery.
منابع مشابه
Graft flow unaffected by full occlusion of left anterior descending artery during coronary artery bypass grafting in a porcine model.
BACKGROUND We investigated in a porcine model whether measuring both the flow distal to an anastomosis and the graft transit time flow (TTF) gives a more accurate picture of the true blood flow in the left anterior descending artery (LAD) than graft TTF measurement alone. METHODS We performed off-pump coronary artery bypass grafting (CABG)-left internal mammary artery (LIMA) to the LAD-on 5 Y...
متن کاملHow I do it: high-quality intraoperative fluorescence imaging in off-pump coronary artery bypass grafting.
We have developed a simple technique for establishing high-quality intraoperative fluorescence imaging in off-pump coronary artery bypass grafting. The technique of transaortic injection of indocyanine green is an effective method of achieving clear fluorescence imaging and for evaluating the quality of graft anastomoses. We consider the images obtained with this technique to be equivalent to t...
متن کاملAvoidance of Dialysis in an End-Stage Renal Disease Patient Status-post Off-pump Coronary Artery Bypass Grafting
Certain benefits are clearly associated with the use of off-pump coronary artery bypass grafting (CABG) as compared with the on-pump CABG. The superiority is more evident in patients with multiple co morbidities including renal failure.We reviewed the medical records of a 67-year-old male with a past medical history that was significant for multiple cardiovascular diseases and new-onset end-sta...
متن کاملThe impressive achievements associated with conventional coronary artery bypass grafting (CABG) surgery are largely attributable to an excellent surgical “platform” of factors that combine to facilitate precise anastomotic suturing—full ster-
Background: The current study reviews clinical feasibility experiences evaluating safety and efficacy of using robotic assistance to create a left internal mammary artery to left anterior descending artery (LIMA-to-LAD) anastomosis. Methods: Between August and November 1999, 9 patients (aged 54-73 years) underwent robotically assisted endoscopic coronary artery bypass grafting (E-CABG) after in...
متن کاملMonitoring diastolic dysfunction using a simplified algorithm in patients undergoing off-pump coronary artery bypass grafting surgery
CONTEXT Left ventricle diastolic dysfunction (LVDD) is gaining importance as useful marker of mortality and morbidity in cardiac surgical patients. Different algorithms have been proposed for the intraoperative grading of DD. Knowledge of the particular grade of DD has clinical implications with the potential to modify therapy, but there is a paucity of literature on the role of diastolic funct...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Annals of thoracic surgery
دوره 74 4 شماره
صفحات -
تاریخ انتشار 2002