Differences in cyclic fatigue resistance between ProTaper Next and ProTaper Universal instruments at different levels.

نویسندگان

  • Juan J Pérez-Higueras
  • Ana Arias
  • José C de la Macorra
  • Ove A Peters
چکیده

INTRODUCTION New designs and alloys have been developed to increase cyclic fatigue (CF) resistance of rotary files. The aim of this study was to compare CF resistance of ProTaper Universal (PTU; Dentsply Tulsa Dental, Tulsa, OK) and ProTaper Next (PTN, Dentsply Tulsa Dental) instruments at different points of curvature. METHODS A total of 420 files (240 PTU, S1, F1, F2, and F3 and 180 PTN, X1, X2, and X3) were divided in 14 groups of 30 instruments each. Instruments in groups S1-5, F1-5, X1-5, F2-5, X2-5, F3-5, and X3-5 were tested at 5 mm from the tip. Groups S1-12, X1-12, and F1-12 were tested at 12 mm from the tip because S1, X1, and F1 instruments have the same diameter at that level. Groups F2-8, X2-8, F3-8, and X3-8 were tested at 8 mm (F2/X2 and F3/X3, respectively, had the same diameter at 8 mm). All files were rotated at 300 rpm until fracture. CF resistance was tested in stainless steel curved canals (60°, r = 3 mm). Time to fracture was recorded. The mean half-life and beta and eta were calculated for each group and were compared with Weibull analysis. RESULTS PTN instruments will last significantly longer than PTU files with a probability higher than 98% at all tested levels except for S1, which was the significantly the most resistant instrument to CF at 5 mm from the tip. CONCLUSIONS PTU S1 was significantly the most resistant instrument at 5 mm from the tip. PTN files were significantly more resistant to CF than PTU instruments at all the other tested levels.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cyclic fatigue resistance of two nickel-titanium instruments in different curving angles: a comparative study.

The cyclic resistance of ProTaper Universal (size 25/08) and ProTaper Next (size 25/06) instruments was compared in artificial canals with different curvatures in this study. A total of 30 ProTaper Universal and 30 ProTaper Next instruments were divided into 6 groups (n = 10) and were operated into artificial canals with 3 different angles of curvature (45°, 60°, 90°). The canal length was kept...

متن کامل

The effects of autoclave sterilization on the cyclic fatigue resistance of ProTaper Universal, ProTaper Next, and ProTaper Gold nickel-titanium instruments

Objectives It was aimed to compare the cyclic fatigue resistances of ProTaper Universal (PTU), ProTaper Next (PTN), and ProTaper Gold (PTG) and the effects of sterilization by autoclave on the cyclic fatigue life of nickel-titanium (NiTi) instruments. Materials and Methods Eighty PTU, 80 PTN, and 80 PTG were included to the present study. Files were tested in a simulated canal. Each brand of ...

متن کامل

An in vitro comparison of cyclic fatigue resistance of ProTaper universal and GT series x files

OBJECTIVE The aim of this study was to compare the cyclic fatigue resistance of two nickel-titanium (NiTi) endodontic instruments from ProTaper and GT series X files. STUDY DESIGN Cyclic fatigue test was realized with instruments from ProTaper: F1 and F3 (Denstply Maillefer, Ballaigues, Switzerland) and GT-X: 20.06 and 30.08 (Dentsply Tulsa Dental, Tulsa, Oklahoma, United States of America). ...

متن کامل

Effect of clinical use on the cyclic fatigue resistance of ProTaper nickel-titanium rotary instruments.

The resistance of ProTaper (Dentsply Maillefer, Ballaigues, Switzerland) nickel-titanium rotary instruments to cyclic fatigue was examined after their initial use in straight or curved canals in vivo. These instruments were rotated freely inside a steel phantom until separation. The number of rotations before failure and the lengths of the separated fragments were compared with data derived fro...

متن کامل

Comparison of cyclic fatigue and torsional resistance in reciprocating single-file systems and continuous rotary instrumentation systems.

As compared with continuous rotary systems, reciprocating motion is believed to increase the fatigue resistance of NiTi instruments. We compared the cyclic fatigue and torsional resistance of reciprocating single-file systems and continuous rotary instrumentation systems in simulated root canals. Eighty instruments from the ProTaper Universal, WaveOne, MTwo, and Reciproc systems (n = 20) were s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of endodontics

دوره 40 9  شماره 

صفحات  -

تاریخ انتشار 2014