Multicenter Comparison of Seven 25OH Vitamin D Automated Immunoassays

نویسندگان

  • Giuseppe Lippi
  • Gian Luca Salvagno
  • Antonio Fortunato
  • Mariella Dipalo
  • Rosalia Aloe
  • Giorgio Da Rin
  • Davide Giavarina
چکیده

BACKGROUND The measurement of 25OH vitamin D continues to grow in clinical laboratories. The aim of this multi-center study was to compare the results of seven automated commercial immunoassays with a reference HPLC technique. METHODS One hundred and twenty consecutive outpatient serum samples were centrifuged, divided in aliquots, frozen and shipped to the participating laboratories. 25OH Vitamin D was measured with a reference HPLC system and with seven automated commercial immunoassays (Roche Cobas E601, Beckman Coulter Unicel DXI 800, Ortho Vitros ES, DiaSorin Liaison, Siemens Advia Centaur, Abbott Architect i System and IDS iSYS). RESULTS Compared to the reference method, the regression coefficients ranged from 0.923 to 0.961 (all p<0.001). The slope of Deming fit ranged from 0.95 to 1.06, whereas the intercept was comprised between -15.2 and 9.2 nmol/L. The bias from the reference HPLC technique varied from -14.5 to 8.7 nmol/L. The minimum performance goal for bias was slightly exceeded by only one immunoassay. The agreement between HPLC and the different immunoassays at 50 nmol/L 25OH Vitamin D varied between 0.61 and 0.85 (all p<0.001). The percentage of samples below this cut-off was significantly different with only one immunoassay. CONCLUSIONS The excellent correlation with the reference HPLC technique attests that all seven automated immunoassays may be reliably used for routine assessment of 25OH-D in clinical laboratories. The significant bias among the different methods seems mostly attributable to the lack of standardization and calls for additional efforts for improving harmonization of 25OH-D immunoassays.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

State-of-the-art vitamin D assays: a comparison of automated immunoassays with liquid chromatography-tandem mass spectrometry methods.

BACKGROUND Vitamin D testing is increasing worldwide. Recently several diagnostic manufacturers including Abbott and Siemens have launched automated 25-hydroxy vitamin D (25OH-D) immunoassays. Furthermore, preexisting assays from DiaSorin and Roche have recently been modified. We compared the performance of 5 automated immunoassays, an RIA and 2 liquid chromatography-tandem mass spectrometry (L...

متن کامل

P-45: Predictive Value of Follicular Fluid VitaminD on Assisted Reproductive TechniqueOutcome

Background: Vitamin D, a steroid hormone, has critical roles in human health. The available data thus identify vitamin D as an important substance in processes involved in reproductive success and thereby suggest pathophysiological mechanisms for reproductive compromise in the setting of vitamin D deficiency. Realizing the prevalence of vitamin D insufficiency in our country, we hypothesized th...

متن کامل

Are 25(OH) D concentrations associated with asthma control and pulmonary function test?

Background: The relationship between vitamin D and asthma is still under investigation. We aimed to evaluate the association between serum vitamin D levels and clinical characteristics of asthma, and the impact of vitamin D deficiency on the clinical manifestations, as them being the issues of debate. Methods: Patients who were admitted to the outpatient clinics of Chest Diseases Department of...

متن کامل

Hypercalcemia and elevated concentration of vitamin D: A case report too easy to be true.

BACKGROUND Endogenous (heterophile, human anti-animal …) antibodies are a known cause of interference in immunoassays. CASE REPORT A patient with hypercalcemia and low PTH levels was investigated. The serum 25OH vitamin D (25OHD) concentration was above the analytical range of the automated analyser (>150ng/mL) but serum dilutions were not linear. A myeloma-related monoclonal peak of immunogl...

متن کامل

Vitamin D metabolism in thyrotoxicosis. Therapeutic aspects derived from an old observation

To the Editor: In an article of 2007 about vitamin D deficiency, it was reported that low 25OH-vitD (25hydroxyvitaminD) plasma levels are found in thyrotoxicosis, with thyrotoxicosis being the last in the list of acquired causes of vitamin D deficiency (1). We first demonstrated low 25OH-vitD plasma levels in thyrotoxicosis (2), as well as the fact that the transformation of vitamin D into 25OH...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 34  شماره 

صفحات  -

تاریخ انتشار 2015