Efficacy of a hip protector to prevent hip fracture in nursing home residents: the HIP PRO randomized controlled trial.
نویسندگان
چکیده
CONTEXT Past studies of the efficacy of hip protectors to prevent hip fracture in nursing home residents have had conflicting results, possibly due to potential biases from clustered randomization designs and modest adherence to intervention. OBJECTIVE To determine whether an energy-absorbing and energy-dispersing hip protector would reduce the risk of hip fracture when worn by nursing home residents. DESIGN, SETTING, AND PARTICIPANTS Multicenter, randomized controlled clinical trial in which 37 nursing homes were randomly assigned to having residents wear a 1-sided hip protector on the left or right hip. Participants were 1042 nursing home residents (mean [SD] aged 85 [7] years; 79% women) who consented and adhered to the hip protector use during a 2-week run-in period and were enrolled. Participating facilities were in greater Boston, Massachusetts, St Louis, Missouri, and Baltimore, Maryland from October 2002 to October 2004. Mean duration of participation for nursing home residents was 7.8 months. None were withdrawn because of adverse effects. INTERVENTION(S) Undergarments with a 1-sided hip protector made of a 0.32-cm outer layer of polyethylene (2.7 kg/m3) backed by a hard high-density polyethylene shield (0.95 cm) that was backed by 0.9 kg/m3 of 1.27-kg ethylene vinyl acetate foam. Each facility was visited 3 times per week to assess adherence and provide staff support. MAIN OUTCOME MEASURE Adjudicated hip fracture occurrences on padded vs unpadded hips. RESULTS After a 20-month follow-up (676 person-years of observation), the study was terminated due to a lack of efficacy. The incidence rate of hip fracture on protected vs unprotected hips did not differ (3.1%; 95% confidence interval [CI], 1.8%-4.4% vs 2.5%; 95% CI, 1.3%-3.7%; P = .70). For the 334 nursing home residents with greater than 80% adherence to hip protector use, the incidence rate of hip fracture on protected vs unprotected hips did not differ (5.3%; 95% CI, 2.6%-8.8% vs 3.5%; 95% CI, 1.3%-5.7%; P = .42). Overall adherence was 73.8%. CONCLUSIONS In this clinical trial of an energy-absorbing/shunting hip protector conducted in US nursing homes, we were unable to detect a protective effect on the risk of hip fracture, despite good adherence to protocol. These results add to the increasing body of evidence that hip protectors, as currently designed, are not effective for preventing hip fracture among nursing home residents. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT00058864.
منابع مشابه
Increased use of hip protectors in nursing homes: economic analysis of a cluster randomized, controlled trial.
OBJECTIVES To assess the cost-efficacy of an intervention program aimed at reducing hip fractures. DESIGN Economic evaluation within an 18-month cluster randomized trial. SETTING Forty-nine nursing homes in Hamburg, Germany. PARTICIPANTS Residents with a high risk of falling (intervention group (IG), n=459; control group (CG), n=483). INTERVENTION Education session for nurses, who subse...
متن کاملPredictors of adherence to the use of hip protectors in nursing home residents.
OBJECTIVES To assess predictors of hip-protector use in nursing home residents under usual-care conditions and after intervention consisting of structured education of nurses and nursing home residents and provision of free hip protectors. DESIGN Nested cohort analyses within a cluster randomized, controlled trial with 18 months follow-up. SETTING Forty-nine nursing home clusters in Hamburg...
متن کاملAcceptability and compliance with wearing energy-shunting hip protectors: a 6-month prospective follow-up in a Finnish nursing home.
OBJECTIVES To assess the acceptability and compliance with use of an energy-shunting hip protector in institutionalized elderly people. DESIGN AND SETTING A 6 month prospective follow-up in a Finnish nursing home. PARTICIPANTS 19 ambulatory nursing home residents with a high risk of hip fracture. MAIN OUTCOME MEASURES The proportion of the residents who were willing to use the device, the...
متن کاملEffectiveness and acceptability of a newly designed hip protector: a pilot study.
Hip fracture has a significant economic and personal cost, involving hospital admission and functional impairment for elderly people. To assess the benefit of using a newly designed hip protector (new material and new design) to prevent fracture in a realistic setting, a randomised intervention-control design was used to trial the effectiveness of pads worn by high falls risk residents (n=71) i...
متن کاملExpression of Concern: Kiel et al. Efficacy of a hip protector to prevent hip fracture in nursing home residents: the HIP PRO randomized controlled trial. JAMA. 2007;298(4):413-422.
WE HEREBY ISSUE AN EXPRESSION OF CONCERN regarding the conduct of the research reported in the article entitled “Efficacy of a Hip Protector to Prevent Hip Fracture in Nursing Home Residents: The HIP PRO Randomized Controlled Trial,” published in the July 25, 2007, issue of JAMA. This study has been the subject of an investigation conducted by the Office for Human Research Protections (OHRP) in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- JAMA
دوره 298 4 شماره
صفحات -
تاریخ انتشار 2007