Proportional-Resonant Control of Doubly-Fed Induction Generator Wind Turbines for Low-Voltage Ride-Through Enhancement

نویسندگان

  • Yan Yan
  • Meng Wang
  • Zhan-Feng Song
  • Chang-Liang Xia
چکیده

A novel control strategy is proposed in this paper for the rotor side converter (RSC) of doubly-fed induction generator (DFIG)-based wind power generation systems. It is supposed to enhance the low-voltage ride-through (LVRT) capability of DFIGs during great-level grid voltage dips. The strategy consists of a proportional-resonant (PR) controller and auxiliary PR controllers. The auxiliary controllers compensate the output voltage of the RSC in case of grid faults, thus limiting the rotor inrush current of DFIG and meeting the requirements of LVRT. Sequential-component decompositions of current are not required in the control system to improve the response of system. Since the resonant compensator is a double-side integrator, the auxiliary controllers can be simplified through coordinate transformation. The feasibility of the control strategy is validated by simulation on a 1.5 MW wind-turbine driven DFIG system. The impact of the RSC converter voltage rating on the LVRT capability of DFIG is investigated. Meanwhile, the influence of angular frequency detection and control parameters are also discussed. Compared with traditional vector control schemes based on PI current controllers, the presented control strategy effectively suppress rotor current and reduce oscillations of DFIG power and torque under grid faults. OPEN ACCESS Energies 2012, 5 4759

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low Voltage Ride Through Enhancement Based on Improved Direct Power Control of DFIG under Unbalanced and Harmonically Distorted Grid Voltage

In the conventional structure of the wind turbines along with the doubly-fed induction generator (DFIG), the stator is directly connected to the power grid. Therefore, voltage changes in the grid result in severe transient conditions in the stator and rotor. In cases where the changes are severe, the generator will be disconnected from the grid and consequently the grid stability will be attenu...

متن کامل

Low Voltage Ride-Through Capability Improvement of Doubly Fed Induction Generator using DVR and SMES

Abstract: With the growth of communities and the increasing need for electricity, and because of the many benefits of renewable energy sources, the wind turbine has become a completely commercial and inevitable process, with increasing penetration into the electricity grid. Distribution networks, on the other hand, are subject to fault that cause power fluctuations and outflow of wind units. In...

متن کامل

A New Method to Enhance the Low Voltage Ride Through Capability of Doubly Fed Induction Generator Using Resistive Type Superconducting Fault Current Limiter

In the event of voltage sag at the nearing of a wind park, severe currents may pass through the power electronic devices of the Doubly Fed Induction Generators (DFIGs). Hence, according to the Low Voltage Ride Through (LVRT) requirements, the wind parks are allowed to disconnect from the network after a certain time. Therefore, to avoid such actions, the LVRT requirement of wind parks is consid...

متن کامل

Unbalanced-Grid-Fault Ride-Through Control for a Doubly Fed Induction Generator Wind Turbine with Series Grid-Side Converter

The grid codes now require doubly fed induction generator (DFIG) wind turbines having the “low voltage ride-through (LVRT)” capability. However, a traditional DFIG with a partially rated back-to-back converter has inherent difficulties to ride through the grid faults, especially for the unbalanced grid faults. Modifications to the traditional DFIG configuration for ride-through have become nece...

متن کامل

GA-Based Optimal LQR Controller to Improve LVRT Capability of DFIG Wind Turbines

Nowadays, the doubly-fed induction generators (DFIGs) based wind turbines (WTs) are the dominant type of WTs connected to grid. Traditionally the back-to-back converters are used to control the DFIGs. In this paper, an Indirect Matrix Converter (IMC) is proposed to control the generator. Compared with back-to-back converters, IMCs have numerous advantages such as: higher level of robustness, re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012