Level of 8-OHdG in drained dialysate appears to be a marker of peritoneal damage in peritoneal dialysis
نویسندگان
چکیده
PURPOSE Peritoneal dialysis (PD) is a successful renal replacement therapy; however, long-term PD leads to structural and functional peritoneal damage. Therefore, the monitoring and estimation of peritoneal function are important in PD patients. Oxidative stress has been implicated as one possible mechanism of peritoneal membrane damage. The aim of this study was to evaluate the association between an oxidative stress marker, 8-hydroxydeoxyguanosine (8-OHdG), and peritoneal damage in PD patients. METHODS The authors evaluated 8-OHdG in drained dialysate by enzyme immunoassay to investigate the association between 8-OHdG and solute transport rate estimated by peritoneal equilibration test and matrix metalloproteinase-2 (MMP-2) level in 45 samples from 28 PD patients. RESULTS The 8-OHdG level was significantly correlated with dialysate:plasma creatine ratio (r = 0.463, P < 0.05) and significantly inversely correlated with D/D0 glucose (where D is the glucose level of peritoneal effluents obtained 4 hours after the injection and D0 is the glucose level obtained immediately after the injection) (r = -0.474, P < 0.05). The 8-OHdG level was also significantly correlated with MMP-2 level (r = 0.551, P < 0.05), but it was not correlated with the age of subjects, the duration of PD, or blood pressure. CONCLUSION The level of 8-OHdG in drained dialysate may be a useful novel marker of peritoneal damage in PD.
منابع مشابه
Matrix metalloproteinase levels in the drained dialysate reflect the peritoneal solute transport rate: a multicentre study in Japan.
BACKGROUND Long-term peritoneal dialysis (PD) leads to peritoneal injury with high solute transport of the peritoneal membrane. At worst, peritoneal injury leads to encapsulating peritoneal sclerosis with an extremely high mortality rate. To perform PD safely and adequately, it is necessary to monitor peritoneal injury. The aim of this study was to investigate the potential of matrix metallopro...
متن کاملDeveloping a Device for Automated Peritoneal Dialysis
Background: Peritoneal dialysis (PD) is an efficient alternative for hemodialysis. Removal of waste metabolites and excess water from the blood circulation are the two main tasks done during dialysis. These are done by using a filter; in PD, the naturally semi-permeable peritoneal membrane acts as the filter. Automated PD machines control intelligently the operations to enhance the efficiency a...
متن کاملPeritoneal equilibration test at home.
The peritoneal equilibration test (PET) has been widely used as a standardized means for estimating solute transport. However, the procedure is rather complex, and patients must spend more than half a day in the hospital. The fast PET is an alternative method, but the results are not reliable in patients whose peritoneal catheters drain poorly. We postulated that patients could perform the PET ...
متن کاملLong daytime exchange in children on continuous cycling peritoneal dialysis: preservation of drained volume because of icodextrin use.
Daytime exchanges with glucose osmotic agents often lead to dialysate reabsorption, poor ultrafiltration (UF), positive sodium balance, and restricted purification of uremic toxins. We studied 5 anuric children on continuous cycling peritoneal dialysis (mean age: 10 years, 10 months), comparing icodextrin to a conventional glucose-based dialysate. The same fill volume (980 +/- 290 mL/m2) and th...
متن کاملEffects of anaesthesia on fluid and solute transport in a C57BL6 mouse model of peritoneal dialysis.
BACKGROUND Genetically modified mice show promise as animal models for studying the physiology and pathophysiology of the peritoneum during peritoneal dialysis (PD). Methods for evaluation of the functional characteristics of the mouse peritoneum have not been studied extensively, and the effects of anaesthesia on fluid and solute transport in mouse models of PD are unknown. METHODS A single ...
متن کامل