Bone-anchored hearing aid implant location in relation to skin reactions.

نویسندگان

  • Hubert T Faber
  • Maarten J F de Wolf
  • Jacky W J de Rooy
  • Myrthe K S Hol
  • Cor W R J Cremers
  • Emmanuel A M Mylanus
چکیده

OBJECTIVE To evaluate the effect of implant location and skin thickness on the frequency and degree of adverse skin reactions around the abutment. DESIGN Retrospective multivariate analysis of implant position related to skin thickness and clinical variables. SETTING Tertiary referral center. PATIENTS Random sample of 248 patients with bone-anchored hearing aids. INTERVENTIONS Bone-anchored hearing aid implant placement by means of the linear incision technique. MEAN OUTCOME MEASURES Type and number of skin reactions and implant loss. RESULTS The mean (SD) distance from the external auditory ear canal to implant was 48.8 (8.0) mm (range, 29-84 mm). The mean skin thickness was 5.5 (1.9) mm. Severe skin reactions (Holgers classification, 2-4) were seen in 46 of the 248 patients (18.5%). Implant loss occurred in 4 patients (1.6%). Three implants were lost owing to failed osseointegration (1.3%), and another implant was removed because of deterioration of cochlear function (0.9%). No implant was lost as a result of infection. CONCLUSION Implant location and skin thickness were not correlated with implant loss or the frequency or degree of adverse skin reactions around the abutment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intralesional triamcinolone acetonide injection in hypertrophic skin surrounding the percutaneous titanium implant of a bone-anchored hearing aid.

OBJECTIVE We present a patient with persistent hypertrophic skin surrounding the percutaneous implant of a bone-anchored hearing aid system, successfully treated with intralesional applied corticosteroids. METHOD Case report and review of the world literature concerning bone-anchored hearing aid implantation and intralesional applied corticosteroids for the treatment of hypertrophic scars and...

متن کامل

A Novel Bone Conduction Implant System

Bone conduction is the process by which an acoustic signal vibrates the skull bones to stimulate the cochlea. Patients with pure conductive hearing loss, mixed hearing loss, and single sided deafness are sometimes poorly rehabilitated by conventional air conduction hearing aids due to for example the functionality losses in the middle ear. With these hearing impairments, the cochlea may functio...

متن کامل

Clinical Outcome of a Wide-diameter Bone-anchored Hearing Implant and a Surgical Technique With Tissue Preservation

OBJECTIVE To investigate the clinical outcome of a surgical technique with tissue preservation for a wide bone-anchored hearing implant concerning postoperative complications, skin reactions, implant loss, and implant stability. STUDY DESIGN Consecutive, prospective case series. SETTING Tertiary referral center. PATIENTS Twenty-four adult patients with normal skin quality were enrolled. ...

متن کامل

Simplified technique without skin flap for the bone-anchored hearing aid (BAHA) implant.

Aim of this report is to present a new surgical technique for the BAHA system implant and to discuss the operational techniques and complications related to this type of surgery. The common technique for the positioning of the Bone-Anchored Hearing Aid (BAHA, Cochlear Limited, Englewood, CO, USA) titanium implant into the temporal bone is based on the use of either a free or a pedunculated skin...

متن کامل

A New Wide-Diameter Bone-Anchored Hearing Implant—Prospective 1-Year Data on Complications, Implant Stability, and Survival

OBJECTIVE To investigate a new wide bone-anchored hearing implant considering initial stability, stability over time, implant loss, and skin reaction. STUDY DESIGN Consecutive, prospective case series. SETTING Tertiary referral center. PATIENTS Twenty adult patients were enrolled. All operations were 1-stage, single-incision technique with subcutaneous reduction. INTERVENTION(S) Measure...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of otolaryngology--head & neck surgery

دوره 135 8  شماره 

صفحات  -

تاریخ انتشار 2009