Depth-Enhanced Maximum Intensity Projection

نویسندگان

  • José Díaz
  • Pere-Pau Vázquez
چکیده

The two most common methods for the visualization of volumetric data are Direct Volume Rendering (DVR) and Maximum Intensity Projection (MIP). Direct Volume Rendering is superior to MIP in providing a larger amount of properly shaded details, because it employs a more complex shading model together with the use of user-defined transfer functions. However, the generation of adequate transfer functions is a laborious and time costly task, even for expert users. As a consequence, medical doctors often use MIP because it does not require the definition of complex transfer functions and because it gives good results on contrasted images. Unfortunately, MIP does not allow to perceive depth ordering and therefore spatial context is lost. In this paper we present a new approach to MIP rendering that uses depth and simple color blending to disambiguate the ordering of internal structures, while maintaining most of the details visible through MIP. It is usually faster than DVR and only requires the transfer function used by MIP rendering.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Maximum Intensity Projection at

Maximum Intensity Projection (MIP) is a volume rendering technique which is used to extract high-intensity structures from volumetric scalar data. At each pixel the highest data value encountered along the corresponding viewing ray is determined. MIP is commonly used to extract vascular structures from medical MRI data sets, i.e., angiography. The usual way to compensate for the loss of spatial...

متن کامل

Real-Time Maximum Intensity Projection

Maximum Intensity Projection (MIP) is a volume rendering technique which is used to extract high-intensity structures from volumetric data. At each pixel the highest data value encountered along the corresponding viewing ray is determined. MIP is commonly used to extract vascular structures from medical MRI data sets (angiography). The usual way to compensate for the loss of spatial and occlusi...

متن کامل

Three-dimensional evaluation of the lamina cribrosa using spectral-domain optical coherence tomography in glaucoma.

PURPOSE To introduce a novel, digital, three-dimensional (3D) reconstruction of the optic nerve head (ONH) and to use this method to evaluate the 3D configuration of the lamina cribrosa (LC) in patients with primary open-angle glaucoma. METHODS Optic discs of 137 eyes of 137 patients with open-angle glaucoma were scanned with enhanced depth-imaging spectral domain-optical coherence tomography...

متن کامل

Advanced High-Quality Maximum Intensity Projection for Volume Visualization

Maximum Intensity Projection (MIP) is a volume rendering technique which is used to extract high-intensity structures from volumetric data. At each pixel the highest data value encountered along the corresponding viewing ray is determined. MIP is commonly used to extract vascular structures from medical MRI data sets (angiography). Due to lack of depth information in MIP images, animation of th...

متن کامل

Automatic Peripheral Vessel Tracking in 3D Contrast-enhanced MR Angiography

Introduction Three dimensional Contrast-enhanced MR Angiography (3D CE-MRA) has become an accepted technique for vascular imaging particularly in the abdomen, thorax and extremities. This technique can provide 3D angiograms of excellent contrast and minimize flow-related artifacts. However, quantitative 3D morphological information on vessels cannot be easily obtained by simple visualization to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010