Scar dechanneling: new method for scar-related left ventricular tachycardia substrate ablation.

نویسندگان

  • Antonio Berruezo
  • Juan Fernández-Armenta
  • David Andreu
  • Diego Penela
  • Csaba Herczku
  • Reinder Evertz
  • Laura Cipolletta
  • Juan Acosta
  • Roger Borràs
  • Elena Arbelo
  • Jose María Tolosana
  • Josep Brugada
  • Lluis Mont
چکیده

BACKGROUND Ventricular tachycardia (VT) substrate ablation usually requires extensive ablation. Scar dechanneling technique may limit the extent of ablation needed. METHODS AND RESULTS The study included 101 consecutive patients with left ventricular scar-related VT (75 ischemic patients; left ventricular ejection fraction, 36 ± 13%). Procedural end point was the elimination of all identified conducting channels (CCs) by ablation at the CC entrance followed by abolition of residual inducible VTs. By itself, scar dechanneling rendered noninducibility in 54.5% of patients; ablation of residual inducible VT increased noninducibility to 78.2%. Patients needing only scar dechanneling had a shorter procedure (213 ± 64 versus 244 ± 71 minutes; P = 0.027), fewer radiofrequency applications (19 ± 11% versus 27 ± 18%; P = 0.01), and external cardioversion/defibrillation shocks (20% versus 65.2%; P < 0.001). At 2 years, patients needing scar dechanneling alone had better event-free survival (80% versus 62%) and lower mortality (5% versus 11%). Incomplete CC-electrogram elimination was the only independent predictor (hazard ratio, 2.54 [1.06-6.10]) for the primary end point. Higher end point-free survival rates were observed in patients noninducible after scar dechanneling (log-rank P = 0.013) and those with complete CC-electrogram elimination (log-rank P = 0.013). The complications rate was 6.9%, with no deaths. CONCLUSIONS Scar dechanneling alone results in low recurrence and mortality rates in more than half of patients despite the limited ablation extent required. Residual inducible VT ablation improves acute results, but patients who require it have worse outcomes. Recurrences are mainly related to incomplete CC-electrogram elimination.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Combined endocardial and epicardial catheter ablation in arrhythmogenic right ventricular dysplasia incorporating scar dechanneling technique.

BACKGROUND Ventricular tachycardia (VT) ablation in patients with arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) has a low success rate. A more extensive epicardial (Epi) arrhythmogenic substrate could explain the low efficacy. We report the results of combined endocardial (Endo) and Epi VT ablation and conducting channel (CC) elimination. METHODS AND RESULTS Eleven consec...

متن کامل

Prognostic Value of Scar Imaging for€Substrate Ablation of Ventricular€Tachycardia

SEE PAGE 353 C atheter ablation for ventricular tachycardia (VT) in ischemic heart disease is considered standard therapy in patients with recurrent, sustained monomorphic ventricular tachycardia, usually after failed antiarrhythmic therapy. Many centers worldwide use pre-procedural imaging with cardiac magnetic resonance (CMR) to assess the “scar substrate” in patients with ischemic and non-is...

متن کامل

Scar characteristics derived from two- and three-dimensional reconstructions of cardiac contrast-enhanced magnetic resonance images: Relationship to ventricular tachycardia inducibility and ablation success

BACKGROUND The relationship between cardiac contrast-enhanced magnetic resonance imaging (CE-MRI)-derived scar characteristics and substrate for ventricular tachycardia (VT) in patients with structural heart disease (SHD) has not been fully investigated. METHODS This study included 51 patients (mean age, 63.3±15.1 years) who underwent CE-MRI with SHD and VT induction testing before ablation. ...

متن کامل

Images in Cardiovascular Medicine Improving Safety of Epicardial Ventricular Tachycardia Ablation Using the Scar Dechanneling Technique and the Integration of Anatomy, Scar Components, and Coronary Arteries Into the Navigation System

A 54-year-old patient with a nonischemic cardiomyopathy, mild left ventricular dysfunction, and a nonsyncopal ventricular tachycardia was admitted for an ablation procedure. Preprocedural contrast-enhanced cardiac magnetic resonance (ce-CMR) was performed with a 3T clinical scanner (Magnetom Trio, Siemens Healthcare, Erlangen, Germany). A free-breathing 3-dimensional navigator and electrocardio...

متن کامل

Three-dimensional contrast-enhanced multidetector CT for anatomic, dynamic, and perfusion characterization of abnormal myocardium to guide ventricular tachycardia ablations.

BACKGROUND Advances in contrast-enhanced multidetector CT enable detailed characterization of the left ventricular myocardium. Myocardial scar and border zone (BZ), as the target of ventricular tachycardia ablations, displays abnormal anatomic, dynamic, and perfusion characteristics during first-pass CT. This study assessed how contrast-enhanced CT can predict voltage-defined scar and BZ and in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Arrhythmia and electrophysiology

دوره 8 2  شماره 

صفحات  -

تاریخ انتشار 2015