Effect of Pressurized Cement Insertion on Cardiopulmonary Parameters during Cemented Hip Hemiarthroplasty: A Randomized Prospective Study

نویسندگان

  • Woo Suk Song
  • Joon Cheol Choi
  • Tae Hyun Kim
  • Sang Hoon Oh
  • Sub Ri Park
  • Byoung Hark Park
چکیده

PURPOSE We aimed to investigate the cardiopulmonary effects of pressurized cement insertion in elderly patients undergoing cemented hip hemiarthroplasty. MATERIALS AND METHODS We conducted a randomized prospective study on elderly patients undergoing cemented hip hemiarthroplasty. Patients were divided into pressurized and non-pressurized groups based on the pressure application during cement insertion. We measured mean arterial blood pressure (MAP), systolic blood pressure (SBP), diastolic blood pressure (DBP), heart rate (HR), arterial blood gases and serotonin concentration in blood. These variables were measured before bone cement insertion, and 3 and 5 minute after insertion. They were also measured immediately and 15 minutes after reduction. RESULTS In cemented hip hemiarthroplasty, there were no significant change in MAP (P=0.92), SBP (P=0.85), DBP (P=0.98), HR (P=0.97) and serotonin concentration over time. There were no statistically significant difference between the two groups in MAP, SBP, DBP, HR, PO2, PaCO2, SaO2 and serotonin concentration, though three minutes after cement insertion, both groups showed decreases in SBP, DBP and MBP. CONCLUSION The pressurization method in cemented hip hemiarthroplasty was not found to be related with development of bone cement syndromes in elderly patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hemodynamic and Arterial Blood Gas Parameters during Cemented Hip Hemiarthroplasty in Elderly Patients

Background:  Patients undergoing cemented hip hemiarthroplasty may develop bone cement implantation syndrome (BCIS) which is a leading cause of intraoperative complications. The purpose of this study was to evaluate cardiovascular changes during cemented hip hemiarthroplasty in elderly patients.   Methods:  Cemented hip hemiarthroplasty was performed on 72 patients with femoral neck fracture. A...

متن کامل

Medullary lavage reduces embolic phenomena and cardiopulmonary changes during cemented hemiarthroplasty.

We randomised 24 patients before they had a cemented hemiarthroplasty for hip fracture to receive either thorough or minimal saline lavage of the femoral canal. We then determined the effect in each group on the thromboembolic and cardiopulmonary responses to the pressurised insertion of cement, using transoesophageal echocardiography to show the echogenic embolic response. We found a statistic...

متن کامل

Cardiac output during hemiarthroplasty of the hip. A prospective, controlled trial of cemented and uncemented prostheses.

In a prospective, controlled study, we measured the effect on cardiac output of the introduction of methylmethacrylate during hemiarthroplasty for displaced fractures of the femoral neck. We treated 20 elderly patients who were similar in age, height, weight and preoperative left ventricular function with either cemented or uncemented hemiarthroplasty. Using a transoesophageal Doppler probe, we...

متن کامل

Hemodynamic and Arterial Blood Gas Parameters during Cemented Hip Hemiarthroplasty in Elderly Patients.

BACKGROUND Patients undergoing cemented hip hemiarthroplasty may develop bone cement implantation syndrome (BCIS) which is a leading cause of intraoperative complications. The purpose of this study was to evaluate cardiovascular changes during cemented hip hemiarthroplasty in elderly patients. METHODS Cemented hip hemiarthroplasty was performed on 72 patients with femoral neck fracture. All p...

متن کامل

Use of a Digital Protractor and a Spirit Level to Determine the Intraoperative Anteversion of Femoral Component during Cemented Hip Hemiarthroplasty: a Prospective Clinical Trial

Background: Femoral stem anteversion during hip arthroplasty is generally estimated by eye intraoperatively and hasproven to be different from targeted values. This study aims to determine the accuracy of a novel technique using adigital protractor and a spirit level to improve surgeons’ estimation of stem anteversion.Methods: A prospective non-randomized study was conducted a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 26  شماره 

صفحات  -

تاریخ انتشار 2014