In Vivo X-ray Angiography of Mouse Brain using Synchrotron Radiation
نویسنده
چکیده
X-ray angiography using a contrast agent has the main advantage of being able to simultaneously demonstrate the anatomy of vessels and changes in morphology. In rats, morphological changes and different vasoreactivities have been studied by angiography; however, the spatial resolution has not been sufficient to detect detailed changes in vessel diameter. Furthermore, owing to the relatively large volume of contrast agent (300-500 μl) required for such studies, imaging studies could not be repeated in each rat. We previously developed an angiography technique using SPring-8, a third generation synchrotron radiation facil i ty. With highly monochromatic synchrotron radiation as an X-ray source and a newly developed X-ray directconversion-type VIDICON camera, our previous study showed rat cerebral perforating arteries [1]. We, then, for the first time, performed in vivo X-ray angiography of the mouse brain using beamline BL28B2 [2]. A thin PE-50 tube was placed in the unilateral external carotid artery in adult male C57Black/6J mice. While maintaining the blood flow in the internal carotid artery, 33 μl of contrast agent was injected, and then selective angiography of the hemisphere was performed. The average diameters of cerebral artery were as follows: 142.5 ± 7.90 in the middle cerebral artery, 138.3 ± 9.35 in the anterior cerebral artery, 120.5 ± 5.53 in the posterior cerebral artery, and 162.6 ± 10.87 in the internal carotid artery (μm, n=5). To demonstrate the changes in diameter, we induced hypercapina and detected the dilatation of the vessels between 121 and 124 % of the original diameters (n=5). We also repeated angiography in the mice before and after intracarotid injection of vasodilatation drugs: papaverine hydrochloride, adenosine 5'triphosphate disodium, and fasudil hydrochloride hydrate. We demonstrated the chronological changes in diameter in each artery 1, 5, 15, and 30 minutes after injection (n = 1 for each drug). As a result, using only a minimum volume of the contrast agent, synchrotron radiation enables us to conduct X-ray angiography of the mouse brain. The morphology of the vessels can be clearly observed under physiological conditions. The diameter of vessels and changes in diameter can also be successfully determined in vivo.
منابع مشابه
In vivo X-ray angiography in the mouse brain using synchrotron radiation.
BACKGROUND AND PURPOSE We, for the first time, performed in vivo x-ray angiography in the mouse brain using SPring-8, a third-generation synchrotron radiation facility. METHODS A thin PE-50 tube was placed in the unilateral external carotid artery in adult male C57BL/6J mice. While maintaining the blood flow in the internal carotid artery, 33 muL of contrast agent was injected and then select...
متن کاملA Review of the Applications of Synchrotron Radiation in Archaeological Sciences
The scientific research regarding investigation, characterization and protection of the archeological specimens is manifested through a notable participation of multidisciplinary subjects and experts, scientists and archeometrists. One of the main principals which are considered by archaeometrists in the study of the precious specimens is the utilizing nondestructive methods. As an example, in ...
متن کاملDetection of breast cancer using non-invasive X-ray diffraction technique of hair: A preliminary study
Background: An early diagnosis of breast cancer relates directly to an accurate treatment plan and strategy. Early detection of breast cancer before its development would be a significant reduction of morbidity and mortality rates. The aim of this preliminary study is to investigate the sensitivity of Wide Angle X-ray diffraction (WAXRD) method on women hair samples of healthy and breast cancer...
متن کاملReal time observation of mouse fetal skeleton using a high resolution X-ray synchrotron
The X-ray synchrotron is quite different from conventional radiation sources. This technique may expand the capabilities of conventional radiology and be applied in novel manners for special cases. To evaluate the usefulness of X-ray synchrotron radiation systems for real time observations, mouse fetal skeleton development was monitored with a high resolution X-ray synchrotron. A non-monochroma...
متن کاملMegavoltage X-ray Dose Enhancement with Gold Nanoparticles in Tumor Bearing Mice
One of the applications of gold nanoparticles (GNPs) in medicine is radiation dose-enhancing effect. Although there are many simulations, in vitro and in vivo evidence that GNPs can enhance significantly the radiation dose effect of orthovoltage beams. These beams compared with megavoltage (MV) beams, have limited applications in radiotherapy. In order to evaluate GNPs radiosensitization perfor...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008