Improved determination of G using two methods.
نویسندگان
چکیده
This Letter describes new work on the determination of the Newtonian constant of gravitation, G, carried out at the BIPM since publication of the first results in 2001. The apparatus has been completely rebuilt and extensive tests carried out on the key parameters needed to produce a new value for G. The basic principles of the experiment remain the same, namely a torsion balance suspended from a wide, thin Cu-Be strip with two modes of operation, free deflection (Cavendish) and electrostatic servo control. The result from the new work is: G=6.67545(18)×10(-11) m3 kg(-1) s(-2) with a standard uncertainty of 27 ppm. This is 21 ppm below our 2001 result but 241 ppm above The CODATA 2010 value, which has an assigned uncertainty of 120 ppm. This confirms the discrepancy of our results with the CODATA value and highlights the wide divergence that now exists in recent values of G. The many changes made to the apparatus lead to the formal correlation between our two results being close to zero. Being statistically independent and statistically consistent, the two results taken together provide a unique contribution to determinations of G.
منابع مشابه
IMPROVED CHROMATOGRAPHIC METHOD FOR DETERMINATION OF SODIUM DICLOFENAC IN INJECTABLE SOLUTION AND PREDICTION OF CHEMICAL STABILITY
Two modified methods for assaying sodium diclofenac were developed by GC and HPLC. Diclofenac was converted into methyl ester derivative by methyl iodide in acetone. The ester was extract and subjected to GLC with flame ionization detector. %5 SE-30/chrom W-HP (80-100 mesh) was used as a column in GC. For reversed phase HPLC, the mobile phase was methanol and water (55-45). The separation was p...
متن کاملComparison of Microbiological and High-Performance Liquid Chromatographic Methods for Determination of Clarithromycin Levels in Plasma
An agar well diffusion bioassay method for determination of clarithromycin in human plasma, using Micrococcus Luteus ATCC 9341 as the assay organism, was compared with a selective high-performance liquid chromatographic (HPLC) method with UV detection. Spiked plasma was used to prepare standard and control samples for both methods. The results of the bioassay analyses with spiked plasma samples...
متن کاملComparison of Microbiological and High-Performance Liquid Chromatographic Methods for Determination of Clarithromycin Levels in Plasma
An agar well diffusion bioassay method for determination of clarithromycin in human plasma, using Micrococcus Luteus ATCC 9341 as the assay organism, was compared with a selective high-performance liquid chromatographic (HPLC) method with UV detection. Spiked plasma was used to prepare standard and control samples for both methods. The results of the bioassay analyses with spiked plasma samples...
متن کاملSpectrophotometric Determination of Pantoprazole Sodium in Pharmaceuticals Using N-Bromosuccinimide, Methyl Orange and Indigo Carmine as Reagents
Two sensitive spectrophotometric methods are presented for the assay of pantoprazole sodium sesqui hydrate (PNT) in bulk drug and in formulations using N-bromosuccinimide (NBS) and two dyes, methyl orange and indigo carmine, as reagents. The methods involve the addition of a known excess of NBS to PNT in acid medium, followed by determination of unreacted oxidant by reacting with a fixed a...
متن کاملP-242: Sex Determination in ICSI Oocytes with Two Polar Bodies Using PGD and FISH, A Case Report
Background: Morphology and presence of Polar body in the oocyte are denoting oocyte quality and is used as a criterion for prognosis of embryo quality. However, little is known about ICSI result of oocytes with two polar bodies. The present study reports the result of ICSI in a case having several oocytes with two polar bodies. Materials and Methods: A 34 years old patient (K.H.) with history o...
متن کاملDetermination of vancomycin and methicillin resistance in clinical isolates of Staphylococcus aureus in hospitals of Ilam city
Introduction: In this study, using the phenotypic and genotypic methods, oxacillin susceptibility in Staphylococcus aureus (S. aureus) strains isolated from patients at two government hospitals in Ilam, Iran was tested. Materials and methods: Out of 200 S. aureus isolates from different human clinical specimens consisting of blood (31%), wound (20%), urine (21%), catheters (7%), sputum (12...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physical review letters
دوره 111 10 شماره
صفحات -
تاریخ انتشار 2013