Detection via laser desorption and mass spectrometry of multiplex electrophore-labeled albumin.
نویسندگان
چکیده
Albumin was reacted with a mixture of six electrophore N-hydroxysuccinimide esters, each of which possessed an interior glycolketo linkage. The purpose of this linkage is to release the attached electrophore as a ketone when heated, due to a thermal retro-aldol reaction. The multiplex electrophore-labeled albumin was detected as a dried spot deposited on a polyimide membrane by laser desorption/capillary collection (of the released ketone electrophores)/off-line gas chromatography/electron capture-mass spectrometry. This encourages further study of such electrophore labels in immunoassays and related techniques, where there is a need to make advances in multi-analyte detection.
منابع مشابه
Electrophore mass tag dideoxy DNA sequencing.
Toward a goal of dideoxy sequencing DNA utilizing electrophore labels, we prepared four electrophore-labeled DNA oligonucleotide primers. Each primer has a different electrophore and DNA sequence but a common glycol keto (alpha,beta-dihydroxyketo) release group. Cleavage of this latter group by either periodate oxidation or a thermal retroaldol reaction releases the electrophores for detection ...
متن کاملMultiplex protein detection with DNA readout via mass spectrometry.
Multiplex protein quantification has been constrained by issues of assay specificity, sensitivity and throughput. This research presents a novel approach that overcomes these limitations using antibody-oligonucleotide conjugates for immuno-polymerase chain reaction (immuno-PCR) or proximity ligation, coupled with competitive PCR and MALDI-TOF mass spectrometry. Employing these combinations of t...
متن کاملSample depletion of the matrix-assisted laser desorption process monitored using radionuclide detection.
To investigate analyte consumption during the laser desorption process, matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) is combined with radionuclide detection. Radionuclide detection provides highly sensitive and quantitative information on the amount of radiolabeled analytes in a MALDI MS sample spot. 14C-Labeled cytochrome c is deposited with 2,5-dihydroxybenzoic aci...
متن کاملMultiplex detection of human herpesviruses from archival specimens using MALDI-TOF mass spectrometry
متن کامل
Simultaneous Detection and Identification of Enteric Viruses by PCR-Mass Assay
Simultaneous detection of enteric viruses that cause similar symptoms (e.g. hand, foot and mouth disease) is essential to the prevention of outbreaks and control of infections. In this study, a novel PCR-Mass assay combining multiplex polymerase chain reaction (PCR) with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) was developed and used for simult...