Assessment of left ventricular volumes and ejection fraction with 16-slice multi-slice computed tomography; comparison with 2D-echocardiography.

نویسندگان

  • J D Schuijf
  • J J Bax
  • J W Jukema
  • H J Lamb
  • L P Salm
  • A de Roos
  • E E van der Wall
چکیده

BACKGROUND In recent years, multi-slice computed tomography (MSCT) has emerged as a rapidly expanding modality for non-invasive assessment of coronary artery disease. Simultaneously, left ventricular (LV) function can be evaluated although this is not yet a routine component of an MSCT examination. Accordingly, the purpose of the present study was to validate assessment of LV function with MSCT using 2D-echocardiography in a large cohort of patients. METHODS In 70 patients (57 male, 13 female), 16-slice MSCT was performed (Toshiba Aquilion 16, Japan) followed by retrospective analysis of global LV function. For these measurements, 2D-echocardiography served as the standard of reference. RESULTS For LV volumes, excellent correlations for both end-diastolic volume (EDV) (r=0.97) and end-systolic volume (ESV) (r=0.98) were obtained by linear regression analysis. At Bland-Altman analysis, mean differences (+/-standard deviations) of -1.4 ml+/-11.3 ml and -3.0 ml+/-7.7 ml were observed between MSCT and 2D-echocardiography for LV EDV and LV ESV respectively. As a result, LV EF was slightly overestimated with MSCT (1.7%+/-4.9%, P<0.05). Correlation between the two techniques was excellent (r=0.91). CONCLUSION In a large cohort of patients, an excellent correlation was observed between 16-slice MSCT and 2D-echocardiography in the evaluation of LV volumes and EF. The addition of LV function analysis to the anatomical MSCT data may potentially enhance the diagnostic and prognostic value of the technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of global and regional left ventricular function and volumes with 64-slice multi-slice computed tomography: a comparison with 2D echocardiography

Introduction: In patients with coronary artery disease (CAD), LV function and volumes are important parameters for long-term prognosis. 64-slice MSCT allows non-invasive assessment of the coronary arteries, but the accuracy of 64-slice MSCT for assessment of LV volumes and function is unknown. Methods: A head-to-head comparison between 64-slice MSCT and 2D echocardiography was performed in 40 p...

متن کامل

Real-time three-dimensional echocardiographic left ventricular systolic assessment: side-by-side comparison with 64-slice multi-detector cardiac computed tomography.

AIMS To investigate by real-time 3D echocardiography (RT3DE) and cardiac computed tomography (CCT) the analysis of left ventricle ejection fraction (LVEF) and volumes. METHODS AND RESULTS A total of 67 patients (37 males, 55 +/- 11 years) were studied prospectively by RT3DE and by 64-slice CCT. RT3DE data: LVEF ranged from 30 to 78.6% (63.1 +/- 7.33); left ventricular end-diastolic volume (LV...

متن کامل

Assessment of global left ventricular systolic function with multidetector CT and 2D echocardiography: a comparison between reconstructions of 1-mm and 2-mm slice thickness at multidetector CT.

PURPOSE To compare multidetector computed tomography (MDCT) and two-dimensional transthoracic echocardiography (2DE) for left ventricular ejection fraction (EF); and to make comparison between reconstructions of 1-mm and 2-mm slice thickness at MDCT in left ventricular analysis by using a semiautomated segmentation algorithm. MATERIALS AND METHODS In 43 patients global left ventricular systol...

متن کامل

Prediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography

Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...

متن کامل

Assessment of global left ventricular function and volumes with 320-row multidetector computed tomography: A comparison with 2D-echocardiography

BACKGROUND Multidetector computed tomography (MDCT) has been demonstrated as a feasible imaging modality for noninvasive assessment of coronary artery disease and left ventricular (LV) function. Recently, 320-row systems have become available with 16 cm anatomical coverage allowing image acquisition of the entire heart within a single heartbeat. The purpose of this study was to evaluate the acc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of cardiology

دوره 116 2  شماره 

صفحات  -

تاریخ انتشار 2007