Validation of Omron HBP-1300 professional blood pressure monitor based on auscultation in children and adults

نویسندگان

  • Linghui Meng
  • Di Zhao
  • Yan Pan
  • Wenqing Ding
  • Qing Wei
  • Hua Li
  • Pingjin Gao
  • Jie Mi
چکیده

UNLABELLED BACKGROUnD: To determine whether the professional Omron HBP-1300 blood pressure (BP) monitor meets American Association for the Advancement of Medical Instrumentation (AAMI) accuracy standards in Chinese children and adults. METHOD According to the AAMI protocol, simultaneous auscultatory measurements by two observers using a mercury manometer were obtained in participants using the Omron HBP-1300. Triple measurements were obtained after a minimum 5-min rest with a 1-min interval between adjacent measurements. RESULTS A total of 85 participants submitted to 255 doctor-measured BP and 255 successful professional monitor readings. The initial auscultation systolic BP was <100 mmHg in 25 participants (29.4%), 100-160 mmHg in 53 participants (62.4%), and >160 mmHg in seven participants (8.2%). All of the simultaneous measurements agreed to within ± 10 mmHg, while 95% agreed to within ± 4 mmHg for both systolic and diastolic BP, and the consistency between two observers was satisfactory. The difference between the devices was -1.3 ± 3.6 mmHg for systolic BP and 0.7 ± 3.8 mmHg for diastolic BP and by AAMI method 1, which met this guideline. The average difference between two devices by AAMI method 2 was 1.4 ± 3.2 mmHg for systolic BP and 1.0 ± 3.9 mmHg for diastolic BP, which met this guideline. CONCLUSION The professional BP monitor Omron HBP-1300 is desirable for measuring the BP for Chinese children and adults.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quality Control and Validation of Oscillometric Blood Pressure Measurements Taken During an Epidemiological Investigation

This study aims to validate blood pressure (BP) values measured by an oscillometric BP monitor and seek possible calibration methods if discrepancies exist. Noninvasive BP measurement outcomes were determined using an oscillometric BP monitor (Omron HBP-1300) versus a mercury sphygmomanometer (standard device). Two percent of subjects enrolled in an epidemiological investigation were systematic...

متن کامل

Validation study of an automated wrist monitor, omron model HEM-608, compared with the standard methods for blood pressure measurement.

OBJECTIVE - The aim of our study was to assess the profile of a wrist monitor, the Omron Model HEM-608, compared with the indirect method for blood pressure measurement. METHODS - Our study population consisted of 100 subjects, 29 being normotensive and 71 being hypertensive. Participants had their blood pressure checked 8 times with alternate techniques, 4 by the indirect method and 4 with the...

متن کامل

[Evaluation of the Omron 705-CP blood pressure measuring device for use in adolescents and young adults].

OBJECTIVE To assess the Omron 705-CP monitor for measuring blood pressure in adolescents and young adults. METHODS According to the protocols of the British Hypertension Society and the Association for the Advancement of Medical Instrumentation, we performed validation of the device in 60 adolescents. The Omron monitor was connected in Y to a mercury column. Four consecutive and simultaneous ...

متن کامل

Validation of the RisingSun RS‐651 Blood Pressure Monitor Based on Auscultation in Adults According to the ANSI/AAMI/ISO 81060‐2:2013 Standard

This study validated the RisingSun RS-651 blood pressure (BP) monitor based on auscultation in adults according to the American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization (ANSI/AAMI/ISO) 81060-2:2013 standard. The RS-651 device was evaluated in a study of 97 participants. The same arm simultaneous method...

متن کامل

Changing relationship between home and office blood pressure with increasing age in children: the Arsakeion School study.

BACKGROUND Home blood pressure (HBP) monitoring is being used in children. However, there is no information on the relationship between HBP and office measurements (Office BP (OBP)) in this population. METHODS This school-based study investigated the effect of age on the difference between HBP and OBP in 765 healthy subjects aged 6-18 years (mean age 12 +/- 3 (SD years)). HBP (3 days, 12 read...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2016