Quantitative Analysis of Corneal Energy Dissipation and Corneal and Orbital Deformation in Response to an Air-Pulse in Healthy Eyes.

نویسندگان

  • Hans R Vellara
  • Noor Q Ali
  • Akilesh Gokul
  • Jason Turuwhenua
  • Dipika V Patel
  • Charles N J McGhee
چکیده

PURPOSE To examine and evaluate ocular biomechanical metrics and additionally derived corneal and orbital components using a noncontact Scheimpflug-based tonometer (CorVis ST) in a population of healthy eyes. METHODS A total of 152 eyes of 152 participants were examined by slit-lamp biomicroscopy, corneal tomography, and the CorVis ST (CST). This determined the distribution of outputs from the CST, such as deformation amplitude (DA), and additionally derived parameters, including maximum corneal deformation (MCD), maximum orbital deformation (MOD), and corneal energy dissipation (CED). RESULTS The mean age of participants was 35.88 ± 13.8 years. Deformation amplitude significantly correlated with age (r = 0.24, P = 0.002) but not sex or ethnicity (P > 0.05). Multiple linear regression analysis revealed significant correlations between DA and age (r = 0.19, P = 0.006) and DA and IOP (r = -0.59, P < 0.001). Age correlated with MCD (r = 0.20, P = 0.01), MOD (r = 0.18, P = 0.03), and CED (r = 0.39, P < 0.001). Males had a lower MOD than females (0.24 vs. 0.26 mm, respectively, P = 0.01); however, there were no differences in MCD or CED between sexes (P > 0.05). There were no significant differences between ethnicities for MCD, MOD, and CED (P > 0.05). Multiple linear regression analysis revealed significant correlations between MCD and IOP (r = -0.65, P < 0.001), CED and age (r = 0.41, P < 0.001), CED and IOP (r = 0.28, P = 0.001), and between CED and central corneal thickness (CCT) (r = -0.36, P < 0.001). CONCLUSIONS The isolation of the corneal component (MCD) should be used when analyzing deformation characteristics in diseases that only affect the cornea. This study establishes a baseline for a population of healthy eyes. Future publications will identify differences in MCD, MOD, and CED between healthy and diseased populations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A 3-decade Activity of the Central Eye Bank of Iran

Purpose: To report a 3-decade eye bank data and activity of the Central Eye Bank of Iran (CEBI). Methods: All the eye bank records in terms of procured eyes, utilized tissues, corneal transplants per capita, and indications for keratoplasty over the last 3 decades were analyzed. Results: During the last 27 years, 115 743 whole eyes were donated, among which 114 169 eyes were donated between 199...

متن کامل

ویژگی‌های بیومکانیکی قرنیه در بیماران مبتلا به کراتوکونوس و ارتباط آن با شدت بیماری

Background and Objective: Keratoconus is a disorder in cornea characterized by constant thinning and prominence that can result in vision defect. Due to ultrasonic changes in the corneal structure caused by keratoconus disease, its rigidity and biomechanical properties are subject to some changes. In this regard, the present study was conducted to determine the correlation of biomechanical feat...

متن کامل

Fusion of Different Corneal Parameters to Improve the Diagnosis of Keratoconus

Purpose: To diagnose keratoconus from healthy eyes, as well as suspected keratoconus. Methods: Certain parameters were extracted from Casia, Corvis, and Pentacam HR devices for 3 groups of healthy, with keratoconus, and suspected keratoconus. This study was performed on 340 eyes with keratoconus, 310 normal eyes, and 350 suspected keratoconus. The processing method involved the fusion of featur...

متن کامل

Chemical Corneal Burning due to an Elective Otoplasty in a Boxer Puppy

Case  Description- A  3-month-old  female  intact  Boxer  dog  was  presented  to  the  Veterinary  Hospital  of  Shahid Bahonar  University  of  Kerman  with  a  complaint  epiphora,  photophobia  and  corneal  opacity  of  both  eyes.  Clinical Findings-  Ophthalmic  examination  revealed  mild  blepharospasm  and  mucoid  discharge  of  both  eyes,  with  severe  bilateral  chemosis  and  c...

متن کامل

Non-linear Dynamic Analysis of Steel Hollow I-core Sandwich Panel under Air Blast Loading

In this paper, the non-linear dynamic response of novel steel sandwich panel with hollow I-core subjected to blast loading was studied. Special emphasis is placed on the evaluation of midpoint displacements and energy dissipation of the models. Several parameters such as boundary conditions, strain rate, mesh dependency and asymmetrical loading are considered in this study. The material and geo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 56 11  شماره 

صفحات  -

تاریخ انتشار 2015