Relationship between socket pressure and EMG of two muscles in trans-femoral stumps during gait.
نویسندگان
چکیده
The biomechanical interaction between the leg stump and the prosthetic socket is critical in achieving close-to-normal ambulation. Although many investigations have been performed to understand the biomechanics of trans-tibial sockets, few studies have measured the socket interface pressure for transfemoral amputees. Furthermore, no report has examined how the residual muscle activities in the transfemoral stump affect the socket interface pressure characteristics during gait. In this study, an experimental method was developed to measure the trans-femoral socket interface pressures and EMG of muscles in the stumps of two trans-femoral amputees. Also, the measurement of three-dimensional prosthetic locomotion was synchronized to understand detailed socket biomechanics. Based on the experimental results, a significant correlation (P < 0.05) was found between the measured temporal EMG amplitude and the interface pressure at the knee flexor (biceps femoris) and extensor (rectus femoris). Therefore, the residual muscle activity of a trans-femoral amputee's stump could be an important factor affecting socket-interface pressure changes during ambulation.
منابع مشابه
Stump-socket interface pressure as an aid to socket design in prostheses for trans-femoral amputees--a preliminary study.
A system for measuring the stump-socket interface pressure was designed and built using a strain gauged type load cell. The system was utilized to study the pressure distribution in the quadrilateral and ischial containment type sockets. Two volunteer trans-femoral amputees fitted with both types of socket participated in the experiments. Pressures were measured while the subjects were standing...
متن کاملA comparison of trans-tibial amputee suction and vacuum socket conditions.
Daily volume loss of the stump leads to a poor fit of the prosthetic socket. A method of preventing this volume loss and maintaining a good fit was developed. A vacuum (-78 kPa) was drawn on the expulsion port of a total surface-bearing suction socket to hold the liner tightly against the socket. Stump volume of 10 trans-tibial amputees was measured prior to and immediately after a 30 minute wa...
متن کاملرابطه فعالیت الکترومیوگرافی و تغییر ضخامت عضلات دیواره ی طرفی شکم در حین انقباض عضلات کف لگن در زنان سالم
Objective: To asses relationship between abdominal muscles superficial Electromyography (EMG) and ultrasound measurement during Pelvic Floor Muscles (PFM) contraction in healthy people. Methods: 15 healthy women participated in the study. Their abdominal muscles activation (transversus abdominis, internal oblique and external oblique muscles) was measured by EMG and sonography during maximal ...
متن کاملCalibration problems encountered while monitoring stump/socket interface pressures with force sensing resistors: techniques adopted to minimise inaccuracies.
Force sensing resistors (FSR) have been used to measure dynamic pressures at the interface between appliance and patient. Inaccuracies using FSRs have been reported. This paper summarises both the calibration problems encountered and the techniques adopted to minimise inaccuracies. It is considered that, by calibrating the transducers attached to the socket, and by adopting a strict test protoc...
متن کاملEngineering a trans-tibial prosthetic socket for the lower limb amputee.
INTRODUCTION This review addresses the different prosthetic socket designs for trans-tibial amputees, the biomechanics behind the designs and the current state of the field. Of particular focus is the classic patella-tendon bearing (PTB) socket and the more recent sockets manufactured using pressure casting techniques and the theory, biomechanics and clinical implications of the two designs. Me...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Prosthetics and orthotics international
دوره 29 1 شماره
صفحات -
تاریخ انتشار 2005