Simultaneous MR and Ultrasound Imaging

نویسندگان

  • Kullervo Hynynen
  • Rajiv Chopra
  • Laura Curiel
چکیده

Magnetic Resonance Imaging (MRI) has excellent soft-tissue contrast, multi-planar imaging capability, and sensitivity to subtle changes in tissue morphology and function Ultrasound imaging, on the other hand, has high temporal resolution volumetric imaging capabilities, the ability to quantify of blood flow, and detect boundaries with small acoustic impedance differences. In addition ultrasound devices have low cost, and portability. Traditionally MR and ultrasound imaging have been performed in different clinical sessions and the information has been compared by the reader. In more advanced cases co-registration of the two image sets have been performed. Although both of the imaging sets can be performed in the same patient position with a short time interval there are advantages in performing the imaging thoroughly simultaneously. The integration of ultrasound (US) imaging and Magnetic Resonance Imaging (MRI) into a single imaging system has not yet been implemented clinically. Some work has been reported concerning the integration of US and MR imaging systems. A synchronization procedure between MRI and US was proposed [1] in order to perform Doppler measurements in between MR pulses. However, no imaging was performed and no MRI compatible system was developed. The use of a commercial US device electrically shielded while used in a 1.5T MR imager has also been proposed [2-4]. In these studies the shielding reduced interference in MRI but was not completely successful and no MRI compatible transducer was used. As well, the US acquisition was not synchronized with the MR imaging. The basic technical issues related to simultaneous ultrasound and MR imaging were recently investigated and it was found that simultaneous imaging is possible without decreasing the image quality of either method [5]. This was achieved by selecting the ultrasound transducer materials such that they are MRI compatible and by synchronizing the ultrasound data collection during the time between the frequency encoding gradient and the subsequent RF pulse and filtering the RF signal of the ultrasound system As a conclusion simultaneous ultrasound and MR imaging may have several advantages to improve diagnosis. Although the technical feasibility has been demonstrated, it has not yet been explored in clinical practice

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Compensation of brain shift during surgery using non-rigid registration of MR and ultrasound images

Background: Surgery and accurate removal of the brain tumor in the operating room and after opening the scalp is one of the major challenges for neurosurgeons due to the removal of skull pressure and displacement and deformation of the brain tissue. This displacement of the brain changes the location of the tumor relative to the MR image taken preoperatively. Methods: This study, which is done...

متن کامل

Hybrid ultrasound/magnetic resonance simultaneous acquisition and image fusion for motion monitoring in the upper abdomen.

OBJECTIVES The combination of ultrasound (US) and magnetic resonance imaging (MRI) may provide a complementary description of the investigated anatomy, together with improved guidance and assessment of image-guided therapies. The aim of the present study was to integrate a clinical setup for simultaneous US and magnetic resonance (MR) acquisition to obtain synchronized monitoring of liver motio...

متن کامل

Imaging of parathyroid lesions with radionuclides - Is it worth doing?

Parathyroid adenomas, or hyperplasia may be present in patients with hypercalcemia. Treatment Is by surgical excision, but about 10% of the lesions may be In ectopic locations. Pre-operative localization of the lesions with non-lvasive imaging, using radionuclides, ultrasound, CT, or MR], may simplify surgery, and reduce patient morbidity. However, the reports of the accuracy of the curre...

متن کامل

Magnetic resonance acoustic radiation force (impulse) imaging (MR-ARFI)

Background/introduction MR-ARFI adds to the rich toolbox of MR imaging methods for guiding focused ultrasound. MRI has exquisite soft tissue contrast for targeting focused ultrasound and a variety of contrast mechanisms for assessing the effect of focused ultrasound. In addition, MR can provide temperature mapping in near-realtime. MR-ARFI is an imaging method that compliments these other capab...

متن کامل

Design, Evaluation and Prototyping of a New Robotic Mechanism for Ultrasound Imaging

This paper presents a new robotic mechanism for ultrasound imaging. The device is placed on a patient's body by an operator, and an ultrasound expert controls the motions of the device to obtain ultrasound images. The paper focuses on the robotic mechanism that performs ultrasound imaging. The design of the mechanism is based on two approaches to produce center of motion for an ultrasound probe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007