Measurement of Retinal Blood Flow Using Fluorescently Labeled Red Blood Cells1,2,3
نویسندگان
چکیده
Blood flow is a useful indicator of the metabolic state of the retina. However, accurate measurement of retinal blood flow is difficult to achieve in practice. Most existing optical techniques used for measuring blood flow require complex assumptions and calculations. We describe here a simple and direct method for calculating absolute blood flow in vessels of all sizes in the rat retina. The method relies on ultrafast confocal line scans to track the passage of fluorescently labeled red blood cells (fRBCs). The accuracy of the blood flow measurements was verified by (1) comparing blood flow calculated independently using either flux or velocity combined with diameter measurements, (2) measuring total retinal blood flow in arterioles and venules, (3) measuring blood flow at vessel branch points, and (4) measuring changes in blood flow in response to hyperoxic and hypercapnic challenge. Confocal line scans oriented parallel and diagonal to vessels were used to compute fRBC velocity and to examine velocity profiles across the width of vessels. We demonstrate that these methods provide accurate measures of absolute blood flow and velocity in retinal vessels of all sizes.
منابع مشابه
Measurement of Retinal Blood Flow Using Fluorescently Labeled Red Blood Cells.
Blood flow is a useful indicator of the metabolic state of the retina. However, accurate measurement of retinal blood flow is difficult to achieve in practice. Most existing optical techniques used for measuring blood flow require complex assumptions and calculations. We describe here a simple and direct method for calculating absolute blood flow in vessels of all sizes in the rat retina. The m...
متن کاملDetection of altered membrane phospholipid asymmetry in subpopulations of human red blood cells using fluorescently labeled annexin V.
The phospholipids of the human red cell are distributed asymmetrically in the bilayer of the red cell membrane. In certain pathologic states, such as sickle cell anemia, phospholipid asymmetry is altered. Although several methods can be used to measure phospholipid organization, small organizational changes have been very difficult to assess. Moreover, these methods fail to identify subpopulati...
متن کاملEffect of erythrocyte aggregation on velocity profiles in venules.
A recent whole organ study in cat skeletal muscle showed that the increase in venous resistance seen at reduced arterial pressures is nearly abolished when the muscle is perfused with a nonaggregating red blood cell suspension. To explore a possible underlying mechanism, we tested the hypothesis that red blood cell aggregation alters flow patterns in vivo and leads to blunted red blood cell vel...
متن کاملIn vivo micro-circulation measurement in skeletal muscle by intra-vital microscopy.
BACKGROUND Regulatory factors and detailed physiology of in vivo microcirculation have remained not fully clarified after many different modalities of imaging had invented. While many macroscopic parameters of blood flow reflect flow velocity, changes in blood flow velocity and red blood cell (RBC) flux does not hold linear relationship in the microscopic observations. There are reports of disc...
متن کاملTechniques for the observation and measurement of red blood cell velocity in vessels of the guinea pig cochlea.
Fluorescence techniques combined with intravital microscopy provide a powerful approach to the study of cochlear blood microcirculation. In the current study, fluorescein isothiocyanate conjugated to high molecular weight dextrans was added to plasma to enhance the visual contrast of flowing blood in microscopic images from the guinea pig cochlea. Photometric signals, obtained from video pictur...
متن کامل