Analysis of TCM injections using the Agilent 1290 Infinity LC system

ثبت نشده
چکیده

An ultra high performance liquid chromatography (UHPLC) method using an Agilent 1290 Infinity LC system with an Agilent 1290 Infinity Diode Array Detector (DAD) was developed for the separation of Shenmai injections. Good separation of complex systems was achieved by connecting two columns: an Agilent ZORBAX Eclipse Plus C18 column (2.1 mm × 100 mm, 1.8 μm) and an Agilent ZORBAX SB C18 (2.1mm × 50 mm, 1.8 μm) column. These were chosen for their separation efficiency and good chromatogram peak shape. The results demonstrated that this analytical method was simple, sensitive and reliable for rapidly analyzing TCM injections, and is helpful in comprehensively evaluating the quality of the TCM injection. Authors Zhixiu Xu Agilent Technologies Shanghai Shanghai 200131 China Application Note Traditional Chinese Medicine

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast screening of mobile and stationary phases with the Agilent 1290 Infinity LC and seamless method transfer to an Agilent 1200 Series LC using ISET

This Application Note describes how the Agilent 1290 Infinity LC System Method Development Solution was used to find optimum separation conditions for degradation products of a pharmaceutical preparation. Having evaluated the optimum combination, a transfer to conventional conditions was performed. Finally, the Agilent Intelligent System Emulation Technology (ISET) of the 1290 Infinity LC was u...

متن کامل

High-Resolution Analysis of Intact Triglycerides by Reversed Phase HPLC Using the Agilent 1290 Infinity LC UHPLC System

The Agilent 1290 Infinity LC System with ultraviolet/visible (UV/VIS) Diode Array detection (DAD) is used to analyze triglycerides in soybean oil under non-aqueous reversed phase gradient conditions. The Agilent 1290 Infinity LC System was used for the chromatographic separation of the sample on 3.0 and 2.1 mm id C18 columns, of various lengths, with 1.8-μm packing materials prepared in 600 bar...

متن کامل

Performance Characteristics of the Agilent 1290 Infinity Evaporative Light Scattering Detector

The Agilent 1290 Infinity Evaporative Light Scattering Detector (ELSD) provides a wide detection range for a variety of compounds with excellent sensitivity, down to low-nanogram levels, better efficiency and greater reproducibility. It is perfect for the analysis of semivolatile and nonvolatile compounds and compounds without UV chromophores such as most amino acids and sugars. The 1290 Infini...

متن کامل

Software assisted identification of metabo- lites from pharmaceutical drugs using the Agilent 1290 Infinity LC System with an Agilent 6530 Q-TOF MS System and the expert prediction system Meteor

This Application Note describes: • The separation of metabolites from a pharmaceutical drug on an Agilent 1290 Infinity LC System • The generation of mass spectral data on an Agilent 6530 Accurate-Mass Q-TOF liquid chromatograph/mass spectrometer (LC/MS) • The introduction of results from the expert metabolism prediction software Meteor (Lhasa Limited, Leeds, UK) into the Agilent MassHunter Met...

متن کامل

Fast analysis of ink dyes using the Agilent 1290 Infinity LC System coupled to Agilent 6140 single quadrupole LC/MS System for forensic analysis of ink pens and markers

In forensics, the analysis of ink writings from documentation is required for authentication or crime analysis. Ten organic ink dye components typically found in ink pens were separated using the Agilent 1290 Infinity LC System and quantified using the Agilent 6140 single quadrupole LC/MS System. The dyes were separated in less than 3.5 min using a sub-2-μm, 30 mm column. Analysis of ink markin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010