Performance Comparison of Domestic Refrigerator using HFC134a and HFC134a/HC Refrigerant Mixture
نویسندگان
چکیده
An experimental performance comparison study on domestic refrigerator system was conducted and compared with HFC134a and M09 (HFC134a and HC blend (containing 55.2%HC600a and 44.8%HC290 by weight)) mixture refrigerant. The domestic refrigerator system was initially designed to operate with HFC134a.Experimental results showed that the refrigeration capacity of the refrigerant M09 mixture system had 20.6% higher than R134a system at 32oC atmosphere condition. It was observed that the M09 showed a faster cooling rate than R134a. The COP of M09 mixture system was 7.2% to9.16% higher than R134a system. A reduction in pull down time percentage in the refrigerator Freezer, chiller, Food, Crisper was observed to be about 24.34%, 11.11%, 1.91%, and 7.90 % for M09 system. In per day energy consumption of M09 system was 2.1%lesser than HFC134a system. The temperature variation along the evaporator coil was less than 2.7 oC. The M09 mixtures cool the system 6 minutes earlier than the HFC134a due to its higher heat transfer characteristics. The overall performance has proved that the above M09 refrigerant mixture could be the best long term alternative to phase out R134a.
منابع مشابه
Performance Evaluation of A Household Refrigerator Using Cuo Nanoparticle Lubricant Mixture and Various Other Compressor Oils with Different Condenser Modes
The objective of this paper was to study the performance of household refrigerator having both air and water-cooled condenser, with 0.06% mass fraction CuO nanoparticle-lubricant mixture and different types of compressor oils. The experiment was done using HFC134a as the refrigerant, CuO nanoparticles, Polyol-ester oil (POE) oil which is used as the conventional lubricant in the household refri...
متن کاملReliability Study of HFC134a Compressor for Refrigerator
More than one year has passed since refrigerant for refrigerator was changed from CFC12 to HFC134a. Long term reliability of refrigerator in HFC134a refrigerant system is mainly dependent on lubrication of moving parts of compressor and clogging of capillary tube. To maintain better practical reliability in components in compressor such as refrigeration lubricant,metallic materials and motor in...
متن کاملExperimental Study on the Heat Transfer Performance of a Zeotropic Refrigerant Mixture in Horizontal Tubes
In the present study, the condensation and evaporation heat transfer performance of a zeotropic refrigerant mixture (HFC32/HFC125/HFC134a) inside horizontal tubes with smooth, grooved or cross·grooved inner surfaces was investigated experimentally. The cross-gTOoved tube showed the highest heat transfer coefficient for both condensation and evaporation with the zeotropic mixture. Its heat trans...
متن کاملPerformance Improvement of an Air Conditioning System Using Matrix Heat Exchanger
–The objective of this work is to study the performance of a split air conditioning system with and without a Matrix Heat Exchanger (MHE) .The experiment was done using HFC134a as the refrigerant and Polyol-ester oil (POE) as the conventional lubricant in the air conditioning system. The performance of the split air conditioning system with HFC134a/POE oil system was compared with HFC134a/POE o...
متن کاملAn Experimental Comparison of Evaporation and Condensation Heat Transfer Coefficients for HFC-134a and CFC-12
Evaporation of HFC134a inside smooth, horizontal tubes is studied. Te,;ts are made with pure refngerant and with oil-refrigerant mixtures. Heat flux has varied from 2 kW/n? to 10 kW/m . The inner diameter of the tubes are 12 mm. T1.1o evaporators are used, 4 and 10 m long. Oil content is varied from 0 to 2.5 mass percentage (synthetic oil, EXP-0275). Oil free HFC134a is found to have higher hea...
متن کامل