A Real-Time Motion Compensation Package and Active Marker Headband for Brain MRI
نویسندگان
چکیده
Introduction: Even a few millimeters of patient movement during an MRI exam can result in motion artifacts, manifested as blurring or ghosting, that render the images diagnostically unusable. Often, in subject populations with a high potential diagnostic benefit, e.g. young children, elderly subjects, and patients with dementia, the utility of MRI is curtailed by motion artifacts, underlining the importance of an effective motion correction strategy. Several prospective compensation techniques for brain MRI have been proposed – including image-based methods (1), 3D-navigators (2-4), and optical markers (5). Each technique uses different reference data to solve for the six degrees of freedom (6-DOF) needed to define rigid-body motion. Here, we propose the use of active markers for real-time motion tracking. The tracking of micro RF-coil “active markers” was first introduced in 1986 (6), and later used for motion correction in an “offline” inter-image update scheme (7). Recently, this has been extended into a real-time, intra-image compensation strategy (8), with preliminary results demonstrating quantitative improvement in image quality in moving phantoms (9). The current work presents a complete prospective correction package for brain MRI that requires minimal additional hardware and can be flexibly incorporated into a large family of imaging sequences, promoting transferability to the clinical setting. Methods: Experiments were performed on a 1.5T Philips Achieva (Philips Medical Systems, Best, The Netherlands). The setup for a motion corrected brain exam is shown in Fig. 1. A headband integrated with three active markers is securely placed on the forehead of a volunteer, maintaining a fixed location relative to the head so that any head movement is reflected in the active markers (three points in 3D-space are sufficient to uniquely solve for the 6-DOF). The multi-channel MR system allows for parallel imaging using a standard bird-cage coil (Conn. A), and position tracking with our active marker headband (Conn. B). The tracking-coils were interfaced to the scanner via a vendor-provided Synergy Multi-Connect (SMC) Box. The active marker design and tracking pulse-sequence used for localization has been detailed in a separate submission (current conference), as well as in previous work (10); within the space defined by the bird-cage coil, validation tests have shown marker precision of <10μm. At scan start, the initial locations of the active markers are determined. The tracking sequence is then interleaved into the imaging sequence at a user-adjustable rate. Comparing current active-marker positions with the initial reference locations, the 6-DOF rigid-body motion is determined (11) and fed back to update the gradient currents – thereby maintaining the image-plane at a fixed orientation relative to the head – before the next segment of k-space is acquired. In cases of extreme/abrupt motion, corrupted lines of kspace are rejected and reacquired with the updated geometry (8). This iteration of tracking and imaging continues until all of the desired k-space is acquired. Images are conventionally reconstructed on the MR system, and immediately available for viewing. Prospective correction was applied to a 3D-MPRAGE scan (TE/TR/TI/shot interval = 4/8.3/1000/1500 ms, θ = 8o, FOV = 240×240×100 mm, voxel size = 1.25×1.25×2 mm, slices = 50, turbo factor = 48) to establish the scheme’s effectiveness in even complex sequences; tracking and geometry updates were interleaved every 48 k-space phase-encodes (400 ms of image data acquisition). Two cases were tested, i) with the volunteer at rest, and ii) performing a reproducible ±5o left-right headshake motion throughout the entire scan. For each case, two scans were acquired – with correction ON and OFF – in order to evaluate improvements in image quality under similar motion conditions. Results: Comparison of Fig. 2c vs. 2b demonstrates the dramatic improvement in image quality achieved in the presence of motion, while comparison of Fig. 2b with 2a illustrates virtually perfect correction. A quantitative metric of image quality based on the signal power in the image at high spatial frequencies (9) was calculated for each image volume (Fig. 2a-c), and represented as a percentage Q by normalizing to the at rest, uncorrected volume (images not shown). Results established substantial improvement for both motion corrected scans (Q > 100%), quantitatively confirming positive visual inspection of image quality. It is interesting to note that this metric detected an improvement in image quality with correction ON even with the volunteer at rest, suggesting correction for physiological motion; active marker tracking information during at rest scans contained a frequency cycle matching the respiratory bellows monitor, confirming that the dominant motion was respiration in these cases. The current package has also been tested in both standard/turbo spin-echo and gradient-echo sequences, with very similar results. Discussion & Conclusion: This work demonstrates utilization of active markers in a successful motion detection and real-time correction package for rigid-body motion. High quality images are acquired in the presence of motion, clearly showing the benefits of this approach. The correction scheme allows for intraimage motion compensation, i.e. between single or multiple k-space lines. In contrast, a real-time imagebased correction approach (PACE) (1), is only capable of correcting for inter-image motion, such as between image volumes in an EPI time series. In both PACE and 3D spherical navigator techniques (2,3), long temporal delays (~ 2 s) are required for complicated motion detection measurements and registration calculations, limiting factors in real-time applications. In contrast, active markers require only a short tracking pulse-sequence and computationally simple correction calculation. The total delay is 37 ms, on-par with cloverleaf (4) and optical (5) strategies (18.2 ms and 32 ms, respectively), but without the need for cloverleaf’s 12 s initial reference scan (during which the subject must remain motionless), or the additional hardware requirements of optical tracking. Unlike 2D-PROPELLER (12), our approach is not confounded by through-plane motion and is likely to provide significant improvement in image quality in virtually all situations, even when no excessive motion is present. Utility in other MR applications, for example EPI-based sequences such as DWI, DTI, ASL, and fMRI, will be avenues of future investigation.
منابع مشابه
Real-Time Intra-Volume Motion Correction in EPI Using Active Markers
Introduction: Echo-planar imaging (EPI) is the sequence of choice for functional MRI (fMRI), where rapid scanning is needed in order to continuously acquire complete brain volumes for a time-series analysis. Even a few millimeters of movement during an fMRI scan can result in large, artifactual, signal changes in the timeseries data that will obscure the relatively small brain activation signal...
متن کاملReal-time motion analytics during brain MRI improve data quality and reduce costs
Head motion systematically distorts clinical and research MRI data. Motion artifacts have biased findings from many structural and functional brain MRI studies. An effective way to remove motion artifacts is to exclude MRI data frames affected by head motion. However, such post-hoc frame censoring can lead to data loss rates of 50% or more in our pediatric patient cohorts. Hence, many scanner o...
متن کاملAdvanced Motion Correction Methods in PET
With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...
متن کاملVery Fast Load Flow Calculation Using Fast-Decoupled Reactive Power Compensation Method for Radial Active Distribution Networks in Smart Grid Environment Based on Zooming Algorithm
Distribution load flow (DLF) calculation is one of the most important tools in distribution networks. DLF tools must be able to perform fast calculations in real-time studies at the presence of distributed generators (DGs) in a smart grid environment even in conditions of change in the network topology. In this paper, a new method for DLF in radial active distribution networks is proposed. The ...
متن کاملNew adaptive interpolation schemes for efficient meshbased motion estimation
Motion estimation and compensation is an essential part of existing video coding systems. The mesh-based motion estimation (MME) produces smoother motion field, better subjective quality (free from blocking artifacts), and higher peak signal-to-noise ratio (PSNR) in many cases, especially at low bitrate video communications, compared to the conventional block matching algorithm (BMA). Howev...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008