Undersampling correction for array detector-based satellite spectrometers.

نویسندگان

  • Kelly Chance
  • Thomas P Kurosu
  • Christopher E Sioris
چکیده

Array detector-based instruments are now fundamental to measurements of ozone and other atmospheric trace gases from space in the ultraviolet, visible, and infrared. The present generation of such instruments suffers, to a greater or lesser degree, from undersampling of the spectra, leading to difficulties in the analysis of atmospheric radiances. We provide extended analysis of the undersampling suffered by modern satellite spectrometers, which include the Global Ozone Monitoring Experiment, Scanning Imaging Absorption Spectrometer for Atmospheric Chartography, Ozone Monitoring Instrument, and Ozone Mapping and Profiler Suite. The analysis includes basic undersampling, the effects of binning into separate detector pixels, and the application of high-resolution Fraunhofer spectral data to correct for undersampling in many useful cases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A MAP Estimator for Simultaneous Superresolution and Detector Nonunifomity Correction

During digital video acquisition, imagery may be degraded by a number of phenomena including undersampling, blur, and noise. Many systems, particularly those containing infrared focal plane array (FPA) sensors, are also subject to detector nonuniformity. Nonuniformity, or fixed pattern noise, results from nonuniform responsivity of the photodetectors that make up the FPA. Here we propose a maxi...

متن کامل

An improved high-resolution solar reference spectrum for earth's atmosphere measurements in the ultraviolet, visible, and near infrared

We have developed an improved solar reference spectrum for use in the analysis of atmospheric spectra from vacuum wavelengths of 200.07 through 1000.99nm. The spectrum is developed by combining high spectral resolution ground-based and balloon-based solar measurements with lower spectral resolution but higher accuracy irradiance information. The new reference spectrum replaces our previous refe...

متن کامل

Stray light correction for diode-array-based spectrometers using a monochromator.

Photodiode-array-based spectrometers are increasingly being used in a wide variety of applications. However, the signal measured by this type of instrument often is not what is anticipated by the user and is often subject to contamination from stray light. This paper describes an efficient and low-cost stray light correction approach based on a relatively simple system using a monochromator-bas...

متن کامل

Procedures for Wavelength Calibration and Spectral Response Correction of CCD Array Spectrometers

This work describes a procedure for acquiring a spectrum of an analyte over an extended range of wavelengths and validating the wavelength and intensity assignments. To acquire a spectrum over an extended range of wavelengths with a spectrometer with a charge coupled device (CCD) array detector, it is necessary to acquire many partial spectra, each at a different angular position of the grating...

متن کامل

Calculation of the Scattered Radiation Profile in 64 Slice CT Scanners Using Experimental Measurement

Introduction: One of the most important parameters in x-ray CT imaging is the noise induced by detected scattered radiation. The detected scattered radiation is completely dependent on the scanner geometry as well as size, shape and material of the scanned object. The magnitude and spatial distribution of the scattered radiation in x-ray CT should be quantified for development of robust scatter...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 44 7  شماره 

صفحات  -

تاریخ انتشار 2005